background image

CX163 Installation and User Guide v1.1

4

Safety Information

Important Safety Instructions

Read these instructions.

• 

Keep these instructions.

• 

Heed all warnings.

• 

Follow all instructions.

• 

Do not use this apparatus near water.

• 

Clean only with dry cloth.

• 

Do not block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

• 

Do not install near any heat sources such as radiators, 
heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat.

• 

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If 

the provided plug does not fit into your outlet, consult 

an electrician for replacement of the obsolete outlet.

• 

Protect the power cord from being walked on or 
pinched particularly at plugs, convenience receptacles, 
and the point where they exit from the apparatus.

• 

Only use attachments/accessories specified by the 

manufacturer.

• 

Use only with the cart, stand, tripod, bracket, or 

table specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when moving 
the cart/apparatus combination to avoid injury from tip-
over.

• 

Unplug this apparatus during lightning storms or when 
unused for long periods of time.

• 

Refer all servicing to qualified service personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been spilled or objects have fallen 
into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has 
been dropped.

WARNING:
To reduce the risk of fire or electric shock, do not expose this 

appliance to rain or moisture.

CAUTION:

Use of controls or adjustments or performance of procedures 

other than those specified may result in hazardous radiation 

exposure.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: SHOCK HAZARD - DO NOT OPEN

AVIS: RISQUE DE CHOQUE ÉLECTRIQUE - NE PAS OUVRIR

The lightning flash with the arrowhead symbol within 

an equilateral triangle, is intended to alert you to the 

presence of uninsulated dangerous voltages within the 

product’s  enclosure  that  may  be  of  sufficient  magnitude  to 

constitute a risk of electric shock. 

The exclamation point within an equilateral triangle is 

intended to alert the user to the presence of important 

operating  and  maintenance  (servicing)  instructions  in  the 

literature accompanying the appliance.
Un point d’exclamation dans un triangle équilatéral est destiné 
à alerter l’utilisateur de la présence d’instructions importantes 

sur  le  fonctionnement  et  l’entretien  (la  réparation)  dans  la 

documentation accompagnant l’appareil.

The mains plug is used as the disconnect device and it 

should remain readily accessible during intended use. In 

order to electrically isolate the apparatus from the mains, the 
mains plug should be completely removed from the mains 
outlet socket.
La prise du secteur ne doit pas être obstruée ou doit être 
facilement accessible pendant son utilisation. Pour être 
complètement déconnecté de l’alimentation d’entrée, la prise 
doit être débranchée du secteur.

 Meaning of the label: Evaluation for apparatus only 
based on temperate climate condition, therefore it’s 
the only operating condition applied for the 

equipment .There may be some potential safety hazard if the 
equipment is used in tropical climate region. 
L’évaluation pour les appareils est basée dans une condition 
climatique tempérée, donc c’est la seule condition de 
fonctionnement à appliquer pour l’appareil. Il peut y avoir un 
risque potentiel pour la sécurité si l’équipement est utilisé 
dans une région climatique tropical.

Meaning of the label: Evaluation for apparatus only 
based on altitude not exceeding 2000 m, therefore 
it’s the only operating condition applied for the 

equipment .There may be some potential safety hazard if the 
equipment is used at altitude above 2000 m.
L’évaluation pour les appareils est basée uniquement sur une 
altitude inférieure à 2000 m, donc c’est la seule condition de 

fonctionnement à appliquer pour l’appareil. Il peut y avoir un 
risque potentiel pour la sécurité si l’équipement est utilisé 
avec une altitude au-dessus de 2000 m.

Conformities

This product conforms to the following European EMC 
Standards: 

BS EN 55103-1:2009, BS EN 55103-2:2009

This product has been tested for use in commercial 
and light industrial environments. If the unit is used 
in controlled EMC environments, the urban 

outdoors, heavy industrial environments or close to railways, 
transmitters, overhead power lines, etc., the performance of 
the unit may be degraded.
The product conforms to the following European electrical 
safety standard: 

BS EN 60065:2012

Summary of Contents for CX163

Page 1: ...CX163 Installation and User Guide v1 1 CX163 ZONE MIXER Installation and User Guide ...

Page 2: ...ions 9 Power Supply 9 Fuses and ratings 9 System Connections 9 Music Sources 9 Microphone inputs 10 Zone Outputs 10 Utility Output 10 Music Control 11 Music Mute 11 SETTING UP OPERATION 12 Music Inputs 12 Gain level 12 Local remote control 12 Music EQ 12 Microphone Input 12 Phantom Power 12 Gain level 12 Paging Access Control 12 Mic EQ 13 High pass filter 13 Zone Outputs 13 Stereo and mono operati...

Page 3: ...RL 1 Series remote control plates general considerations 15 Control of music source and level via external DC 15 Fitting loudspeaker EQ cards 15 APPENDIX 16 Application example 16 PCB jumper location and settings 17 Ground loops 18 EMC considerations 18 Technical Specifications 19 ...

Page 4: ...to constitute a risk of electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance Un point d exclamation dans un triangle équilatéral est destiné à alerter l utilisateur de la présence d instructions importantes sur le fonctionnement et ...

Page 5: ...require installation by a qualified person CAUTION Mains Fuse Replace the mains fuse only with the same type and rating as marked on the rear panel Fuse type T1AH 250V Fuse rating 1 A Fuse Size 20 mm x 5 mm CAUTION Servicing The unit contains no user serviceable parts Refer servicing to qualified service personnel Do not perform servicing unless you are qualified to do so Disconnect the power cabl...

Page 6: ...a function that may be required by Local Authority regulations Optional plug in EQ cards may be fitted to any or all zone outputs to optimise the CX163 for use with various installed audio loudspeakers What s in the box Unpack the CX163 and its accessories with care It is always a good idea to store all packaging if practical in case you ever need to return the unit to your Cloud dealer for any re...

Page 7: ...ut in each Zone See Gain level on page 12 3 MICROPHONE LEVEL adjusts level of the mic input in each Zone See Gain level on page 12 4 MUSIC MUTE indicates red when external Music Mute is active See Music Mute on page 11 5 POWER green LED confirms power is applied to the unit 6 Rack mounting ears the unit may be rack mounted in a standard 19 equipment rack It requires 1U of rack height See Hardware ...

Page 8: ...ic EQ on page 13 6 OUTPUTS Z1 and Z2 balanced Left and Right Zone outputs for Zone 1 and Zone 2 See Zone Outputs on page 10 7 ZONE LF and HF preset controls for EQ adjustment in Zone 1 and Zone 2 See Zone EQ on page 13 8 REMOTE LEVEL CONTROL for connection of RL 1 remote control plates to allow remote control of music level in Zone 1 and Zone 2 See Music Control on page 11 9 UTILITY balanced mono ...

Page 9: ...hey can be connected to either the left or right input but the primary Zones should be reconfigured for mono operation see Stereo and mono operation on page 13 The sensitivity range available should allow most standard items of audio equipment such as computers tablets music servers and media receivers etc to operate at a satisfactory level Provided the music source is adjacent to the Zone Mixer n...

Page 10: ... output is designed to drive professional industrial power amplifiers with balanced inputs typically on XLRs In this case wire as the diagram in the next column Note that the screen can be left unconnected at the source end if earth loops are a problem 1 3 SCN pin 1 ground pin 2 hot pin 3 cold Balanced inputs XLRs 1 2 3 2 SC SCN CX163 Balanced output pin 1 ground pin 2 cold pin 3 hot The screen co...

Page 11: ...he other the level at the right output In this case wire the plates as shown below 1 2 3 1 2 3 RL 1 REMOTE LEVEL CONTROL WIRING PLATE USE TWO CORE SCREENED CABLE 4 1 2 3 PLATE LEFT CHANNEL RIGHT CHANNEL CX163 ONLY REMOTE MUSIC CONTROL CONNECTOR RL 1 remote control plates will operate once connected however it may then be desirable to disable the front panel MUSIC LEVEL controls This can be accompl...

Page 12: ...speakers in each zone The EQ controls are marked HF and LF the HF control has a range of 10 dB at 10 kHz and the LF control a range of 10 dB at 50 Hz Note that a flat frequency response is achieved by positioning the slots on the controls in the horizontal plane Microphone Input Phantom Power The microphone input has 12 V phantom power available This will be adequate to power a wide range of conde...

Page 13: ...ter to remove the lowest frequencies This helps to reduce the effects of breath blasts and microphone handling noise The filter is always in circuit Zone Outputs In normal operation the music level in each zone will be set by the front panel MUSIC LEVEL control 2 at Description of front panel on page 7 or by a corresponding control on a remote plate Follow the procedure described previously Gain l...

Page 14: ...umpers Line 6 priority It may sometimes be necessary for one music input to have priority over all the others for example a jukebox in a bar or a digital sound store programmed to make automatic announcements in a public space Line Input 6 may be set to have priority in Zone 1 over whichever source is selected for the zone by its SOURCE control Line 6 priority can be enabled by moving internal PCB...

Page 15: ...emote control plates general considerations Cloud RL 1 Series remote control plates are available in three form factors two fit single gang UK or American electrical back boxes respectively while the third is a 50 x 50 mm Media module suitable for Euro module mounting frames available in most European countries Back boxes of either the recessed type or surface mounting type may be used providing t...

Page 16: ...eas of a pub or bar Each area can set its own volume by means of the local RL 1 remote control panels optional Alternatively it can be set from the front panel of the mixer itself Music at a lower level could be made available to a third area such as the lobby or toilets Paging to either or both zones is achieved using a paging mic such as the Cloud PM4 which would typically be located somewhere o...

Page 17: ...TEREO J8 Zone 1 mono stereo operation STEREO Zone 1 stereo operation MONO Zone 1 L R channels summed STEREO J9 Line 6 priority Zone 1 OFF No priority in Zone 1 ON Line 6 hasVOX triggered priority in Zone 1 over other sources OFF J10 Music ducking release time 3S 3 seconds release time 6S 6 seconds release time ABSENT 12 seconds release time 3S J11 Mic 1 priority trigger Zone 2 VOX Paging mic signa...

Page 18: ...ut leads both left right channels on each line input until the hum disappears This problem is often caused by terminating a screened input cable into a signal source positioned a significant distance from the mixer A good way of avoiding this potential problem is to use signal sources CD players and the like that are double insulated with no connection to the mains supply earth If a signal feed we...

Page 19: ...t Frequency response 3 dB 100 Hz filter to 20 kHz 0 5 dB Distortion 0 05 20 Hz to 22 kHz Gain range 10 dB to 50 dB Input impedance 2 kohms Common mode rejection 70 dB 1 kHz Headroom 20 dB Noise 128 dB EIN 20 Hz to 22 kHz 0dB gain Equalisation LF 10 dB 150 Hz HF 10 dB 5 kHz Outputs Output level nominal 0 dBu Output level max 20 dBu Minimum load impedance 1 2 kohms General Power input 85V to 253V AC...

Page 20: ...www cloud co uk www cloudusa pro ...

Reviews: