147
1.1 Error list
No.
Error message on the
display
Possible cause
Remedy
1
CAN connection faulty
Interruption of CAN bus between
control and operating module
Check plug and connections to the
operating module
Service
2
Error when loading
the job data of the
operating module
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
3
Error when loading the
minimum values of the
operating module
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
4
Error when loading the
maximum values of the
operating module
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
5
Error when loading the
configuration of the
operating module
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
6
Error when loading the
job list
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
7
Error when loading the
version data
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
8
Error during
transmission of the
option code
Operating module cannot call up
the information of the control.
Switch machine Off and On
Check cable connections
Service
9
Characteristic curve
allocation error (only
Eco-Master operating
modules)
May appear after loading new
characteristic curves if material/gas
combinations in the config are set
incorrectly.
Call up characteristic curves again
Check characteristic curve allocation
Service
10
Job does not contain any
data
Job does not exist in the controller.
May appear in case of external job
selection
Check job selection
Create new job
Service
11
Job has wrong check
sum
Error in job file.
Check job selection
Create new job
Service
14
No valid characteristic
curve on weld start
Invalid material/gas combination
and/or process selection.
• ECO/Master: Material/gas LEDs
are blinking.
• Premium: Parameters in the
main menu are shown in red.
Select valid characteristic curve
Service
15
Error in the offsets of
current and voltage
measurement
Error in the digital signal processor
(DSP).
Switch machine Off and On
Service
Summary of Contents for QINEO
Page 4: ......
Page 10: ......
Page 11: ...11 Operational safety Block 1 Operational Safety...
Page 29: ...29 Block 2 Basic information Qineo Champ Pro...
Page 42: ...CHAMP Pro 42...
Page 109: ...109 Block 4 Additional information...
Page 124: ...124 SD module...
Page 138: ...138 Commissioning 6 7 8 5...
Page 140: ...140 Commissioning 7 5 6 The wire inlet must not touch the wire drive roller INFO...
Page 145: ...145 Block 6a Error messages...
Page 159: ...159 Block 6b General maintenance instructions...
Page 164: ...164...
Page 165: ...165 Block 7 Automation...
Page 184: ...184...
Page 185: ...185...
Page 186: ...www qineo de...