3.9.1 Access management
The access management differentiates between two operating levels:
•
Blocked
•
Released
Use this menu to configure which functions are available for the user in
blocked status and whether an access code must be entered to unlock the
welding power source.
Press the "Hold" and "Key" buttons simultaneously until the configuration
menu appears.
Settings
Function
Description
Access code
"No code"
This message appears if no access code is config-
ured.
Locking status
"complete"
The active access to the menus and welding
settings is locked. The menus can only be opened
and viewed.
"Release Fine"
Rotary knob for fine adjustment is released. The
menus are blocked.
"Release Fine, Power"
Both rotary knobs are realised for capacity
adjustment and fine adjustment. The menus are
blocked.
Welding
•
"allowed"
Welding is released without login at the welding
power source.
•
"locked"
Welding is only released after login at the welding
power source.
Call Job* / Call S1-S5
"locked"
The call up of the rapid memories / jobs* is
blocked.
"allowed"
The call up of the rapid memories / jobs* is
released..
Call Job* / Save S1-S5
"locked"
The storage on rapid memories / jobs* is blocked.
"allowed"
The storage on rapid memories / jobs* is released.
*If the option „Job memory MasterPlus“ is activated, the configuration
items "Call job" “ ("blocked" / "allowed") and "Save job" ("blocked" / "al-
lowed") are available.