7.1
dT1_IBH_ON
The temperature difference betw een T1S and T1 for
starting the backup heater.
5
2
10
1
°C
7.2
t_IBH_DELAY
The time that the compressor has run before the first
backup heater turns on
30
15
120
5
MIN
7.3
T4_IBH_ON
The ambient temperature for starting the backup heater
-5
-15
30
1
°C
7.4
dT1_AHS_ON
The temperature difference between T1S and TW2 for
turning the additional heating source on
5
2
10
1
°C
7.5
t_AHS_DELAY
The time that the compressor has run before starting the
additional heating source
30
5
120
5
MIN
7.6
T4_AHS_ON
The ambient temperature for starting the additional
heating source
-5
-15
30
1
°C
7.7
IBH_LOCATE
IBH/AHS installation location PIPE LOOP=0; BUFFER
TANK=1
0
0
0
0
°C
7.8
P_IBH1
Power input of IBH1
0
0
20
0.5
kW
7.9
P_IBH2
Power input of IBH2
0
0
20
0.5
kW
7.10
P_TBH
Power input of TBH
2
0
20
0.5
kW
8.1
T1S_H.A_H
The target outlet w ater temperature for space heating
w hen in holiday aw ay mode
25
20
25
1
°C
8.2
T5S_H.A_DHW
The target outlet w ater temperature for domestic hot
w ater heating w hen in holiday aw ay mode
25
20
25
1
°C
12.1
PREHEATING FOR
FLOOR T1S
The setting temperature of outlet w ater during first
preheating for floor
25
25
35
1
℃
12.3
t_FIRSTFH
The time last for preheating floor
72
48
96
12
HOUR
12.4
t_DRYUP
The day for w arming up during floor drying up
8
4
15
1
DAY
12.5
t_HIGHPEAK
The continue days in high temperature during floor drying up
5
3
7
1
DAY
12.6
t_DRYD
The day of dropping temperature during floor drying up
5
4
15
1
DAY
12.7
T_DRYPEAK
The target peak temperature of w ater flow during floor
drying up
45
30
55
1
℃
12.8
START TIME
The start time of floor drying up
*
0:00 23:30 1/30
h/min
12.9
START DATE
The start date of floor drying up
The
present
date
1-1-
2000
31-12-
2099
1-1-
2001
d/m/y
13.1
AUTO RESTART
COOL/HEAT MODE
Enable or disable the auto restart cooloing/heating mode.
0=NON
,
1=YES
1
0
1
1
/
13.2
AUTO RESTART DHW
MODE
Enable or disable the auto restart DHW mode. 0=NON
,
1=YES
1
0
1
1
/
14.1
POWER INPUT
LIMITATION
The type of power input limitation, 0=NON, 1~8=TYPE 1~8
0
0
8
1
/