252
TBH power
Range 0-200 , default 0 , unit 100W
253
Comfort parameters
Reserved, query the register to report an address error
254
Comfort parameters
Reserved, query the register to report an address error
255
t_ DRYUP
Heating days, setting range: 4~15days , default 8 days
256
t_ HIGHPEAK
Drying days, setting range: 3~7days , default 5 days
257
t_ DRYD
Cooling days, setting range: 4~15days , default 5 days
258
T_ DRYPEAK
Maximum drying temperature, setting range: 30-55°C, default 45°C
259
t_firstFH
The first running time of floor heating , the default value is 72hrs , the setting range:
48-96hrs
260
T1S (first floor heating)
The first floor heating T1S , the setting range: 25 ~ 35°C, the default: 25°C;
261
T1SetC1
9 parameters of refrigeration temperature curve , setting range 5-25°C, default 10°C
262
T1SetC2
9 parameters of refrigeration temperature curve , setting range 5-25°C, default 16°C
263
T4C1
9 parameters of refrigeration temperature curve , setting range (-5)-46°C, default 35°
C
264
T4C2
9 parameters of refrigeration temperature curve , setting range (-5)-46°C, default 25
°C
265
T1SetH1
9 parameters of heating temperature curve , setting range 25-60°C, default 35°C
266
T1SetH2
9 parameters of heating temperature curve , setting range 25-60°C, default 28°C
267
T4H1
9 parameters of heating temperature curve , setting range (-25)-35°C, default -5°C
268
T4H2
9 parameters of heating temperature curve , setting range (-25)-35°C, default 7°C
269
Current frequency limit scheme , 0 : no setting; 1~8 : scheme 1~8 , default 0
270
HB: t_T4_FRESH_C
Range 0.5-6hour , adjustment interval 0.5 , send value = actual value *2
LB: t_T4_FRESH_H
Range 0.5-6hour , adjustment interval 0.5 , send value = actual value *2
271
T _PUMPI_DELAY
Range 2-20 , adjustment interval 0.5 , send value = actual value *2
272
EMISSION TYPE
B it12-15 : region 2 cooling type terminal
B it8-11 : zone 1 cooling type terminal
B it4-7 : region 2 heating type terminal
B it0-3 : zone 1 heating type terminal