CS 3-Phase Installation Manual
Page 17
Figure 7. Service Cable Wiring Diagram for 3-Phase AC
Charging
• The
GROUND
conductor should connect to the Service
Ground terminal lug located at the bottom left corner of the
chassis.
• The
LINE 1
120VAC conductor should connect to the left-
most contactor input terminal labeled “2T1.”
• The
LINE 3
120V AC or 208V AC “Stinger” conductor should
connect to the central contactor input terminal labeled “4T2.”
• The
LINE 2
120VAC conductor should connect to the right-
most contactor input terminal labeled “6T3.”
• The CS 3-Phase requires a dedicated 208/240V AC 50/60Hz,
three phase circuit, with its own dedicated three phase circuit
breaker.
• Do not use a GFCI breaker with the CS 3-Phase. The CS-3
Phase contains a Personnel Protection circuit that is the
equivalent and specifically designed for use with electric
vehicles.
Service Connections
NOTE: Torque specs vary
by configuration and are
specified on the inside of
the CS 3-Phase door.