COMBUSTIBLE GAS LEAK DETECTOR
# 580952
Detects all Hydrocarbon and other Combustible Gases
MSHSA Approved, Intrinsically Safe
User Manual
Introduction
The
580952
features a long life heated sensor
technology that is designed to detect all combustible gases including
Methane, Propane, butane, Acetylene, Alcohol and Gasoline.
The unique digital leak size indicator of the
580952
takes the
guesswork out of whether or not to repair a small leak. The digital
display is independent from the audio alarm and sensitivity level,
allowing the precise pinpointing of the leak source.
The
580952
does not require rechargeable batteries. An optional
detachable LED light will soon be available that clips on to the probe
to facilitate leak detection in low light environments.
Features
Unique numeric leak size indicator
Methane sensitivity < 10ppm
Low battery indicator
Audio mute function
Intrinsically Safe Certified
Bright 3 LED detachable light (optional)
2 year warranty including 2 years on the sensor
Long life, stable sensor
Automatic calibration & reset to ambient
3 adjustable sensitivity levels
Uses 4 AA alkaline batteries
Comfortable Sanoprene grip
CE certified
Made in USA
Gary or Ros OBORNE
Tel: 03 5768 2488 Fax: 03 5768 2688
www.cliplight.com
Leak Size Indicator
The digital leak size indicator remains off normally but once a leak is
detected, a number from 1-9 will be displayed for all combustible
gases
regardless of the sensitivity setting.
The number will continue to increase or decrease depending on the
amount of combustible gas sensed. The maximum value will be
displayed once the leak source has been located.
Low Battery Indicator
Replace the 4 AA alkaline batteries when the red LED on the control
panel is lit. Follow battery installation Instructions under
Maintenance.
Operating Instructions
1.
Turn On:
Press the ON/OFF button once to turn
on and again to turn off
2.
Warm Up:
The detector automatically starts
heating the sensor. During the heating cycle, the
digital leak size indicator will flash
0
and the
detector will sound a slow “beep”. Warm up is
usually less than 10 seconds.
3.
Ready:
The detector is ready to begin searching
for leaks when the flashing
0
stops and the green
sensitivity LED turns on. The audio “beep”
increases in frequency and probe LED begins to
blink steadily.
Audio Mute Function
To silence or mute the audio beep and alarm signal, press the MUTE
button. To restore the audio sound, press the MUTE button again.
Note: a few seconds is required to restore the sound if the mute
button is pressed in rapid succession.