Clinton Electronics CE-PTZ10X User Manual Download Page 7

7

WARNING

TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, SO NOT EXPOSE THIS PRODUCT TO RAIN 

OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS 

OR OTHER OPENINGS ON THE EQUIPMENT.

FCC COMPLIANCE STATEMENT 

FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH 

THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. 

THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL 

INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. 

THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF 

NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE 

HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT 

IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE 

USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.

CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY 

RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS AUTHORITY TO OPERATE THE 

EQUIPMENT.

CE COMPLIANCE STATEMENT 

WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT, THIS PRODUCT 

MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE 

ADEQUATE MEASURES.

CAUTION: BEFORE ATTEMPTING TO CONNECT OR OPERATE THIS PRODUCT, PLEASE READ THE 

LABEL ON THE BOTTOM AND USER’S MANUAL CAREFULLY.

This symbol indicates that dangerous voltage 

constituting a risk of electric shock is present 

within this unit.

This symbol indicates that there are important 

operating and maintenance instructions in the 

literature accompanying this unit.

Technical specifications are subject to change without prior notice. Manual may contain 

mistakes or print errors. All trademarks mentioned belong to their respective owners.

Summary of Contents for CE-PTZ10X

Page 1: ...om v 04 05 10 yboard Adaptor No 14375 2 RS 485 RS232 R RS232 G DC12V RS485 Power RS485 DC12V DC12V Keyboard RJ45 CE PTZ10X RS485 Green Wire RS485 Yellow Wire DVR MUX MENU SET SHOT ALM GRP OFF ON AUTOP...

Page 2: ......

Page 3: ...board Navigation Edit Dome Label Initial Info Display Setup Motion Control Clearing Functions Password Setup Clock Communication Setting Zoom Backlight Shutter Advanced Settings Preset Scan Pattern To...

Page 4: ...90 Tilt range with 1 90 per second and auto flip Stabilized image transfer at 1 s max zoom Built in Camera High Performance zoom camera with digital signal processing High Resolution with real 540TVL...

Page 5: ...ce in any way with the protective foil Please use a dry cloth to clean the inner and outer surfaces For contamination use a natural detergent Improper cleaning method will cause permanent scratches on...

Page 6: ...lean the device when dirty When dirt is hard to remove use a mild detergent and wipe gently Do not operate the device beyond its specified temperature or humidity ratings Do not use the dome camera in...

Page 7: ...E HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPL...

Page 8: ...e transformer stations it is necessary to use additional lightning proof equipment or lightning rod for protection For outdoor installation lightning proof and grounding of the device should be consid...

Page 9: ...ing and avoids possible errors All accessories are tested for maximum compatibility and best performance RS485 Cable The telemetric control of the device uses RS485 serial communication with half dupl...

Page 10: ...nation ON System Keyboard VER34 01 RS 485 Distributor Video Amplifier optional DVR Monitor optional DVR optional Up to 750m coaxial cable Balun Transmitter optional DVR Monitor optional DVR optional U...

Page 11: ...o within system settings menu and how to define Power up action MAIN MENU SYSTEM SETTING CAMERA SETTING FUNCTION SETTING WINDOW BLANKING EXIT S N XXXXXXXXXXXXXXX CLINTON V2 42 PROTOCOL CLINTON DOME AD...

Page 12: ...hanges to display setup EXIT Exit the OSD doing so will save your changes to display setup MOTION The motion control includes the setting for Park Time action and other features AUTO FLIP Disabling th...

Page 13: ...ing this option PASSWORD SETUP In password settings menu you can change the password and enable disable the password protection function The password function can prevent unauthorized access to the OS...

Page 14: ...TNESS Regulate the exposure by changing the brightness control AUTO Automatically regulates the exposure modes WB MODE The camera supports Auto Manual ATW OPW Outdoor and Indoor modes of White Balance...

Page 15: ...the PTZ to desired position and press IRIS OPEN to store or IRIS CLOSE to discard SHOW PRESET This will show the current preset defined in PRESET NUMBER CLEAR PRESET This will delete the current prese...

Page 16: ...gn a name to the current scan defined in SCAN NUMBER BACK Move to previous screen doing so will save your changes to scan EXIT Exit the OSD doing so will save your changes to scan PATTERN A pattern to...

Page 17: ...en doing so will save your changes to tour EXIT Exit the OSD doing so will save your changes to tour ZONES The zone function allows user to define a perimeter with a name tag The perimeter is defined...

Page 18: ...rtain applications It is also known as Privacy Masking which covers the selected area with a blank window This PTZ supports up to 25 masking windows WINDOW NUMBER Current window number EDIT WINDOW Edi...

Page 19: ...XIT CAMERA SETTING ZOOM SPEED HIGH DIGITAL ZOOM ON BLC MODE OFF SLOW SHUTTER OFF ADVANCE SETTING BACK EXIT ADVANCE SETTING AE MODE AUTO SHUTTER N A IRIS N A BRIGHT N A WB MODE AUTO R GAIN N A B GAIN N...

Page 20: ...put VBS 1 0Vp p Sync Negative Y C Output S N Ratio More than 50 dB Pan Speed 0 4 300 per Sec Tilt Speed 0 4 150 per Sec Pan Range 360 Tilt Range 0 90 Communication RS 485 multiple protocol coax Preset...

Page 21: ...21...

Page 22: ...v 01 25 10...

Reviews: