7 COMMISSIONING
7.1
Preliminary operations
Before commissioning the appliance, check that:
– the type of gas is correct for the appliance
– the gas isolation valves for the heating system and the water
system are open
– the system pressure as shown on the pressure gauge when the
system is cold , is between
1 and 1.2 bar
– the pump impeller rotates freely.
7.2
Before commissioning
After having carried out the preliminary operations, perform the
following to start the boiler:
– set the main system switch to "ON"
ON
Fig. 47
– the type of gas for which the boiler has been calibrated,
"nG"
(methane) or
"LG"
(LPG,) will appear followed by the power.
After this the correct representation of the symbols will be
checked and finally
"- -"
will appear on the display
– press the button
s
once for at least 1 second to select "SUM-
MER mode"
l
. The value of the delivery sensor detected at
that moment will appear on the display
– open one or more than one hot water tap. The boiler will work at
maximum power until the taps are closed.
– if there is a fault, the message
"AL"
will appear on the display
followed by the fault code (eg.
"06"
- no flame detected).
m
CAUTION
If the boiler has blocked, restore the start conditions by
pressing and holding the button
o
(
R
) for more than
3 seconds. This operation can be carried out no more
than 6 times.
– close the taps opened previously and check that the appliance
shuts down
– press the button
s
once to select "WINTER mode"
n
. The va-
lue of the heating water temperature detected at that moment
will appear on the display
– adjust the air thermostat and check that the boiler starts and
operates correctly
– to check that the pressure in the network and the nozzles are
correct, the procedure described in section must be carried out
7.3
Parameter setting and display
To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
<
and
o
(approximately 5 seconds) at the
same time until
"tS"
(installer) appears on the 2 digits of the
display which alternate with
"0.1"
(parameter number) and a
"2"
(set value)
Summary of Contents for 24 BF
Page 10: ...10 FR ...
Page 49: ...49 FR ...
Page 58: ...58 EN ...
Page 97: ...97 EN ...
Page 98: ...98 ...
Page 99: ...99 ...
Page 100: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Page 101: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Page 102: ...51 ...
Page 103: ...50 ...
Page 104: ...49 ...
Page 143: ...10 ...