OPERATION AND INSTRUCTION
MANUAL
Swivel Anchor Model: SWY050N
INSPECTION AND MAINTENANCE LOG
MODEL NUMBER:
DATE OF MANUFACTURE:
LABEL LOCATIONS
ClimbTech, LLC.
7303 Burleson Rd. Suite 901 Austin, TX 78744
1(512) 308-6440 / www.climbtech.com
180˚
360˚
8.0”ø
(203.2mm)
2.25”ø
(57.15mm)
5.5”
(139.7mm)
3.0”
(76.2mm)
I
nspection:
O
ffi
cial periodic inspection must be made at least semiannually. The inspection must
be performed by a quali
fi
ed person other than the intended user. If severe weather or
conditions exist then inspections must be carried out more frequently. All inspection
results must be logged in the space provided above.
1. Inspect Swivel to make sure it is
fl
ush with mounting surface.
2. Make sure all labeling is a
ffi
xed to the unit.
3. Inspect anchoring system for signs of damage or wear.
4. Make sure the unit can rotate 360° and D-ring can
fl
ip 180° side to side.
5. Record inspection results in the space provided above.
*If any damage that could a
ff
ect the strength or operation of the device, or
unsafe conditions are found, proper disposal is required. Anchorage connector
must be rendered unusable and then properly discarded.
STEEL MOUNTING: SWY050S
Torque :
45 ft-lbs
(61 Nm)
.5”-13 Lock Nut
.5” Lock
Washer
.5”-13 x 4”
Hex Bolt *
drill .5” (13mm)Ø
.25”
(6mm)
min
3”(76mm)
min fr
om an
y edge
Use
tapered
washer
V2.5-A
Patent # US 8,424,638
Date
Part Number
Comments
Inspector Name
PERFORMANCE:
Tensile Strength (UTS):
5,000-lbf (22kN)
Working Load:
1,000-lbs
(454kg)
DIMENSIONS:
Weight:
1.2-lbs
REGULATORY COMPLIANCE:
ANSI Z359.1-2007,
ANSI Z359.7-2011,
OSHA 1926.502
COMPONENT MATERIALS:
Zinc Plated Steel
US P
ATE
NT 8
,42
4,6
38
U
TS
50
00 L
BF
PLAT
ED
AL
LO
Y
ST
EE
L
M
S
-
XX
X
/M
M-
Y
Y
WARNING:
ALL PERSONS USING THIS EQUIPMENT MUST
READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO
SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD
BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS
EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST
BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE. AVOID
CONTACT WITH PHYSICAL HAZARDS (THERMAL, CHEMICAL,
ELECTRICAL, ETC.). MAKE ONLY COMPATIBLE CONNECTIONS.