
12
confirm.
Step 4.
Select
Date & Time
to edit Control
Panel date and time.
D a t e & T i m e
2 0 1 3 / 0 3 / 2 2 / 0 9 : 1 1
Step 5.
The current date and time will be
displayed, you will begin by editing
year. Press
Up
or
Down
button to
change current year, press
OK
to
continue to edit month/date/hour/
minute.
System Reset
Selecting System Reset will return all Control
Panel setting except Device setting to factory
default value. You will need to reconfigure your
system settings again.
Step 1.
Select
System Reset
and press
OK
to
confirm.
2.8. General Setting
The General Setting menu allows you to
program Control Panel’s alarm related settings
Step 1.
Select
Gen. Setting
and press
OK
to
confirm.
F i n a l D o o r
A r m F a u l t T y p e
T a m p e r A l a r m
E n t r y E x t e n d
E n t r y 1 T i m e
E n t r y 2 T i m e
E x i t T i m e
A l a r m L e n g t h
S u p e r v i s i o n
S o u n d S e t t i n g
Final Door
On:
When the system is Away Armed and
under exit timer countdown, if a opened Door
Contact set to Entry attribute is closed, the
system will automatically arm the system even
if the exit delay timer has not expired yet.
Off:
The system will only arm the system after
the exit delay timer expires. (
Factory Default
)
Step 1.
Select
Final Door
and press
OK
to
confirm.
O f f
O n
Step 2.
Select to turn On or Off the Final Door
option.
Arm Fault Type
Confirm:
When set to
Confirm
, If you attempt
to arm when a fault exists within the system,
the arming action will be prohibited, and a
message will be displayed ―Fault exists! Please
Confirm!‖ You need to arm the system again to
confirm your action and arm the system.
(Factory Default)
Direct Arm:
When set to
Direct Arm
, If you
attempt to arm when a fault exists within the
system, the system will enter selected arm
mode without further notification about fault
events.
Step 1.
Select
Arm Fault Type
and press
OK
to confirm.
C o n f i r m
D i r e c t A r m
Step 2.
Select either Confirm or Direct Arm,
and press
OK
to confirm.
Tamper Alarm
Away Arm:
Tamper alarm will only be
activated when tamper switch is triggered
under Away Arm mode (Tamper event will still
be reported normally in Home/Disarm mode).
(Factory Default)
Always:
Tamper alarm will be activated
whenever tamper switch is triggered.
Step 1.
Select
Tamper Alarm
and press
OK
to
confirm.
A w a y A r m
A l w a y s
Step 2.
Select either Away Arm or Always, and
press
OK
to confirm.
Entry Extend Timer
ON:
If a sensor set to Entry is triggered when
panel is armed, and the system is not disarmed
before Entry Delay Time expires, the panel will
wait for 30 seconds after Entry Delay Time has
expired before reporting burglar alarm and
activating external sirens in the alarm system.
(Factory Default)
OFF:
If a sensor set to Entry is triggered when
panel is armed, and the system is not disarmed
before Entry Delay Time expires, the panel will
report burglar alarm and activate external
sirens in the alarm system immediately when
the Entry Delay Timer has expired.
Step 1.
Select
Entry Extend
and press
OK
to
confirm.
O f f
O n
Step 2.
Select to turn Off or ON the Entry
Extend Timer and press
OK
to confirm.