45
Step 3.
When the CMS operator answers
the call, two-way communication
will be established. Or the test call
can be routed to a voicemail by
CMS.
5.6 Factory Reset
CTC-1052-QT-DT35AW
will
clear
all
programmed parameters by the following
sequence:
Step 1.
Press the Power Button to power off
the panel.
Step 2.
Hold down both the
HELP
&
RESET
buttons while pressing the power
button again to power on the panel.
Keep holding the buttons until one
long beep
is heard, indicating that the
Factory Reset is successful.
Step 4.
Release both buttons.
<NOTE>
Once the
Factory Reset
is executed, all
the programmed data is returned to its
default value and all the devices that have
been learnt-in are removed. You will have
to do the programming and learn-in the
devices one-by-one again.
6. Appendix
6.1. CID Event Code
The message composition for CID Event code is
in the form:
ACCT MT QXYZ GG C
1
C
2
C
3
And is explained in the following table:
100 - Panel emergency
When HELP button is pressed.
101 - Personal emergency
When
the
Wrist
Transmitter
/
Emergency Pendant (WTR) or Fall
Sensor is pressed.
102 - Inactivity
If no sudden movement within 10
seconds after fall detection, an inactivity
code will be sent to Central Monitoring
Station.
111 - Smoke emergency
When the Smoke Detector (SD) is
triggered.
When the Test Button of the Smoke
Where
ACCT
= 4 Digit Account number (0-9)
MT
= Message Type, 18H.
Q
= Event qualifier, which gives specific
event information:
XYZ
= Event code (3 Hex digits 0-9, B-F)
GG
= Group or Partition number (00H)
C
1
C
2
C
3
= 1. For devices: area + zone
C
1
= Area number
0=Area 1,1= Area 2
C
2
C
3
= Zone number
001 Area 1, Zone 1
002 Area 1, Zone 2
…………………..
080 Area 1, Zone 80