Rail Mounting
Audio Matrix Switch is designed to be installed on a standard
35 mm wide DIN rail (EN 50022, BS 5584).
Hook the module from the top, pull down the rail moun ng
clips, push the module to the rail and release the rail
moun ng clips.
Screw Mounting
Screw the module to any surface through 4 corner screw
holes.
3
4
1
2
INSTALLATION GUIDE
version 1.0.1
Compatible with Control4
Audio Matrix Switch
(CL-DR-AMS2X4-N)
Input Voltage
18V-24V DC (24V DC is recommended)
Input Current
170mA (for 24V DC)
I/O Connections
C-Bus
2 X Rj45
Output
4 audio channel-10A per channel
X
rising-cage 5mm screw terminals)
(
Input
2 audio channel-10A per channel
X
rising-cage 5mm screw terminals)
(
Pr
oduc
t Spe
cific
a
on
1
2
3
Change Module Address
In order to change the module address follow steps below consecu vely and uninterruptedly:
1.
Disconnect the main power. Hold bu on #1 & #2 simultaneously (bu on’s and LED’s number
sequence is considered from right to le as shown in following picture).
2.
Reconnect the main power. Release bu on #2 a er LEDs #1 to #4 flashed. Then release bu on
#1 a er LEDs #1 and #2 flashed. Power LED will start flashing quickly.
3.
Press bu on #1, 4 mes. Then the module address will be displayed by LEDs in binary.
4.
Press bu on #1 to increase the module address and bu on #2 to decrease it.
5.
Press bu on #3 to save the module address and bu on #4 to cancel. A er saving the new module
address or canceling the process, the module will reset.
The devices which are connected from a common interface cannot have same module
address.
1
1
1
8
8
4
4
7
6
5
2
1
1. Screw holes
2. Output connectors
3. Input connectors
4. Rail moun ng clips
5. Indicator LEDs
6. Status LEDs
7. Control bu ons (1-4)
8. RS-485 jack
2
3
Compatible with Control4
#1
#2
#3
#4
#1
#2
#3
#4
#5
#6
#7
#8