CH-MG 

Cellular Home Alarm System 

                                                             

Installation and Operation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                                           

3

 

Dec

 

2020

 

Summary of Contents for CH-MG

Page 1: ...CH MG Cellular Home Alarm System Installation and Operation Guide 3 Dec 2020...

Page 2: ...g USB Driver 6 3 4 2 Installing PC Programming Tool 6 4 PROGRAMMING CH MG 7 4 1 PC PROGRAMMING TOOL INSTALLERS ONLY 7 4 1 1 SMS Program 9 4 1 2 APN 9 4 1 3 Wi Fi 10 4 1 4 Report 10 4 1 5 Setting 15 4...

Page 3: ...6 5 CHECK PANEL STATUS 29 6 6 VOICE PROMPTS 30 7 APPENDIX 32 7 1 SMS REMOTE PROGRAMMING COMMANDS TABLE 32...

Page 4: ...a Speech SMS and IP Mobile Network protocols to directly communicate with the monitoring centers CH MG can be programmed by using programming software via RJ 11 connection providing intuitive graphica...

Page 5: ...tus and system status via voice prompt 2 Cancel Alarm Press and hold for 3 seconds Enter Test Mode LED Red Flash During Guard Time LED Blue 1 Flash every 2 seconds In learning mode LED Amber 1 Flash e...

Page 6: ...ng mode Exit learning mode 2 2 Power Supply An AC power adapter is required to connect to a wall outlet Be sure only to use an adapter with the appropriate AC voltage rating to prevent component damag...

Page 7: ...elete its SMS messages whenever the CH MG is powered on To remove SIM card Press and release on the edge of SIM card the card will spring out 3 2 Locating a suitable position for the Control Panel The...

Page 8: ...adapter into the DC Jack of your panel and connect to power supply Press the power button to power on the panel Step 2 Plug the QT cable A into the Programming Telephone Jack of CH MG Step 3 Connect t...

Page 9: ...below Step 1 Make sure CH MG is connected properly please refer to 3 3 Hardware Installation Step 2 Please go to http www ftdichip com Drivers VCP htm Scroll down the webpage and select the driver fi...

Page 10: ...rogramming Tool software via USB port follow instruction below Step 1 Execute the programming tool The following configuration screen will be opened Step 2 Select the following settings in the top sec...

Page 11: ...l None Step 3 Read Configuration To start configuring CH MG settings click on Open A Read configuration success message will pop up click OK to proceed The current CH MG setting will be displayed Clic...

Page 12: ...PN The APN setting must be completed for CH MG to report events via cellular network Click APN to set APN Name APN User and APN Password and click Write to confirm APN Name The name of an access point...

Page 13: ...name Wi Fi Password Enter the Wi Fi password 4 1 4 Report The Report tab allows the user to configure report settings CH MG reports over 3 media IP Mobile Network Speech channel and SMS message 5 Repo...

Page 14: ...ort Destinations according to the designated Report Format JSON reporting http iota medicalguardian com JSON udi Please input the device UDI Unique Device Identifier for JSON Report Maximum of 15 nume...

Page 15: ...rt Indexes programmed within a Group CH MG will report according to the numeric order e g 1 2 3 etc of the Report Index in a Group Report will stop when one report is successful and CH MG will regard...

Page 16: ...to the first group failed going through all the Report Indexes within the group for 3 times CH MG will start reporting to the next group When reporting to the second group succeeds reporting is regar...

Page 17: ...S Text messages sent to user according to the condition of the CH MG SMS text table CH MG Condition SMS Text format Low battery status CH MG Low Battery Battery voltage restored CH MG Battery Restored...

Page 18: ...report This function is only used when a fall is detected if the Help Button on CH MG or the Active Button of the learnt in Fall Sensor is pressed to activate alarm normal guard time is used instead...

Page 19: ...matches with the number s programmed in this function The panel will match the numbers starting from the last digit For example if a number string 321 is programmed the panel will instantly pick up a...

Page 20: ...Users can use the Add Sensor function to include sensors into the Base Click on the Add Sensor button Enter the Sensor ID the barcode on the back of the sensor A sensor ID is a combination of digits 1...

Page 21: ...8 4 1 7 Telemetry Log The Telemetry log tab logs the control panel s detailed cellular connection history 4 1 8 System Log The system log tab logs the control panel s detailed system operation history...

Page 22: ...signal strength The IMEI number of GSM module will be displayed on the right side of GSM signal strength Reboot Device Click Reboot Device to reboot CH MG This will not remove any programmed paramete...

Page 23: ...rt Total elapsed time will be displayed to show how long the updating process has elapsed Step 3 When updating process is completed a message Firmware update success will be displayed in a pop up wind...

Page 24: ...n of the command is completed You can send the command to CH MG now N NO OT TE E If the SMS message text format of your mobile phone is not English please change it to English for SMS remote programmi...

Page 25: ...evice Device Learning and Testing Step 1 Press the Button on RF device to transmit signal Refer to RF device manual for detail Step 2 CH MG will emit 2 beeps when it receives the signal from the penda...

Page 26: ...ion Enter 1 to talk only Enter 2 to open two way voice communication Enter 3 to listen in only Enter 9 to hang up You can also put the handset back to the base cradle to end the call Press CH MG s Hel...

Page 27: ...6 3 Test Mode Test Mode is for user to test if the CH MG can make a successful report to the CMS To enter Test Mode Step 1 Press and hold the Info button for 3 seconds CH MG will emit one beep at 1st...

Page 28: ...s fall detection function is set separately from regular Guard Time This function is only used when a fall is detected if the Active Button of the learnt in Fall Sensor is pressed to activate alarm no...

Page 29: ...evice WTR Fall Sensor or PB once to end the call Press any DTMF key except for the designated hang up key 9 to reset the communication time to 5 minutes When a DTMF key is pressed its designed shortcu...

Page 30: ...f reporting One Report Index can only be assigned to one Group Reporting within a Group If there are multiple Report Indexes programmed within a Group CH MG will report according to the numeric order...

Page 31: ...to the first group failed going through all the Report Indexes within the group for 3 times CH MG will start reporting to the next group When reporting to the second group succeeds reporting is regar...

Page 32: ...r Status reports and will not retry if report failed For example if Groups 1 and 3 are programmed for Status reports Group 1 Group 3 Stops reporting 6 5 Check Panel Status To check CH MG s status pres...

Page 33: ...tion Please call 911 Plays twice if the cellular signal is bad and the system cannot connect to 911 The user need to dial 911 by himself 6 Your alarm is now canceled Reserved 7 Cellular signal good Pl...

Page 34: ...the Info Button once shortly and the system is ready 14 On AC Power Plays once when pressing the Info Button once shortly and the Panel is connected to AC power 15 On Battery Power Plays once when pre...

Page 35: ..._SIA2_UDP 30 SMS_CID 31 SMS_TEXT Miscellaneous Enter 0 for this parameter Event filter 255 all 1 status 4 emergency No report destination Keyword setting KEYWD KEYWD PROG 1111 IPOG To set the keyword...

Page 36: ...ware Upgrade FWUG FWUG PROG 1111 59 124 230 221 53033 img 123 bin 042d Upgrade CH MG firmware by downloading firmware file from server remotely Parameter 1 Server IP Address Max 44 characters Paramete...

Page 37: ...is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible...