Climax Technology Mini-SD-HME User Manual Download Page 1

 

Mini Smoke Detector (Mini-SD-HME) User Manual   

Mini-SD-HME is a mini-sized wireless smoke detector with built-in PIR motion sensor, heat detector and emergency light. 
Mini-SD-HME is designed to protect your family against potential fire hazard.   
 

Parts Identification 

 

1.  IR lens 

2.  LED Indicator & Learn/Test Button/Emergency Light 

Red LED 

  Quick flash: Alarming 

  Flashes every 1 second: Sleep Mode. 

  Flashes every 2 seconds: Under warmup and calibration process.   

  Flashes every 4 seconds with Orange LED: battery exhausted. 

  Flashes briefly: When Learn Button is pressed to see if the device is functioning normally. 

  Lights up briefly: Transmitting signal. 

  Flashes 2 times: When receiving acknowledgement from the Control Panel. 

Orange LED 

  Flashes every 4 seconds with RED LED: battery exhausted. 

  Flashes every 5 seconds: Calibration Failure 

  Flashes every 45 seconds: Low battery condition 

Learn/Test Button 

  Press the button once to: 

  Send a supervision / test signal. 

  Check smoke detection chamber. 

  Silence alarm. 

       

Emergency Light 

  The emergency light will be turned on simultaneously when an alarm is triggered. 

3.  Buzzer 

4.  Mounting Holes 

5.  Battery compartment 

6.  Hooks 

7.  Mounting Holes 

 

Getting Started 

Step 1.

  Put the Control Panel into learning mode. Refer to the Control Panel manual for details. 

Step 2.

  Insert battery to power on the Mini Smoke Detector. 

Step 3.

  The Mini Smoke Detector will emit 2 short beeps and begin warm up for 

1

 minute. The Red LED will flash 

every 2 seconds. 

Step 4.

  During the 1 minute period, press the Learn/Test button once to transmit learn code. The Mini Smoke 

Detector will emit a 2-tone beep. Refer to Control Panel manual to complete learning process. 

Step 5.

  When the Mini Smoke Detector completes warm-up, it will emit a beep to indicate it has entered 

calibration mode. The calibration mode lasts for 

1~9

 minutes. The Red LED will continue to flash every 

two seconds during calibration. Learning the Mini Smoke Detector is 

prohibited

 during this period. 

Step 6.

  When calibration is completed, the Mini Smoke Detector will emit 2 short beeps and turn off LED to return 

to normal mode. If the Mini Smoke Detector is not learnt into panel previously, press the Learn/Test button 
now to complete learning. 