Door Contact (DC-16SL-F1) User Manual
The Door Contact monitors the opening/closing of specified devices (e.g. door or window). The Door Contact is fixed to the
monitored device frame with an actuating magnet fixed to the device. When the door or window opens, the magnet moves
away from the Door Contact, activating an internal magnetic switch causing the Door Contact to transmit alarm signal to the
Control Panel. The device also has the capabilities of communicating signal problems along with low battery situations.
The Door Contact design is consisted of a cover and base. The cover contains all electronics and the base provides a
means for fixing the device.
z
z
I
I
d
d
e
e
n
n
t
t
i
i
f
f
y
y
i
i
n
n
g
g
t
t
h
h
e
e
p
p
a
a
r
r
t
t
s
s
1. LED
Indicator
2.
Learn / Test Button (Top Cover)
- Press the Top Cover to transmit a learn code and enter Test Mode for 3 minutes
3. Battery
Insulator
4. Battery
5.
PCB Board Fixing Screw
- Release the screw to flip over PCB board and access Supervision Jumper if needed.
6.
Supervision Jumper Switch (JP2)
- When the jumper is set as ON, the Supervision is disabled.
- When the jumper is set as OFF, the Supervision is enabled.
(Factory default)
7. Magnet
- Mount the magnet on the left side of the Door Contact The Door Contact should be installed either upright or
inverted to ensure that the rib-marked side faces the magnet.
z
z
L
L
E
E
D
D
I
I
n
n
d
d
i
i
c
c
a
a
t
t
o
o
r
r
In Normal operation mode, the LED indicator remains off except in the following situations:
z
When the Door Contact’s tamper switch is triggered.
z
Every time when the Door Contact is activated with
either Tamper or
Low battery condition.
z
Every time when the Door Contact is activated and transmitting the signal under the Test mode.
z
z
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
i
i
o
o
n
n
z
Enable or Disable the Supervision function using JP2 jumper.
z
When enabled, the Door Contact will automatically transmit Supervisory signals periodically to the Control
Panel at random intervals of 30 to 50 minutes.
If the Control Panel has not received the signal from the Door Contact for a preset period time, the Control
Panel will indicate that particular Door Contact is experiencing an out-of-signal problem.
z
z
B
B
a
a
t
t
t
t
e
e
r
r
y
y
The Door Contact uses one
3V CR2 Lithium battery
as its power source, it is also capable of detecting low battery.
When the battery is low, a low battery signal will be sent to the Control Panel along with regular transmission. The
LED will light up when the Door Contact is activated under low battery status. When battery is exhausted, the Door
Contact will stop all function and the LED will flash every 4 seconds.
Jumper On
The jumper link is inserted
Jumper Off
if the jumper link is removed or “
parked
” on one pin.
Front View
Back View
Internal
PCB Board
Back View