climachill PAC12J User Manual Download Page 1

1/13 

 

USER MANUAL

 

 
Portable Air Conditioner and Heater 
With Heat Pump Technology 

 
 
 
 

 

 
 

 

PAC12J 

 

12,000btu Cool & Heat Portable Air Conditioner 

                                                   

 

 

 

Please read this manual carefully prior to operating the product. 

 

Please keep ALL packaging for duration of Warranty Period

 

 
 

Summary of Contents for PAC12J

Page 1: ...Air Conditioner and Heater With Heat Pump Technology PAC12J 12 000btu Cool Heat Portable Air Conditioner Please read this manual carefully prior to operating the product Please keep ALL packaging for duration of Warranty Period ...

Page 2: ...ot expose skin or eyes directly to cool air for a long period of time 12 If an abnormal odour or smoke comes out of the unit disconnect the unit immediately and contact a qualified service technician 13 When opening the filter cover do not touch the metal parts in the unit s interior 14 Do not immerse the unit in water or any type of liquid Do not use the unit in the immediate surroundings of a ba...

Page 3: ...he sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Warning The unit creates water which is collected in an internal water tank which has a rubber drain plug it is very unlikely but if this tank becomes damaged during tra...

Page 4: ...________________________ Invoice Number _______________________________________________________ WARRANTY This product comes with a 12month warranty from date of purchase as indicated on original sales receipt Please note that it is a warranty condition that ALL of the original packaging is kept for the duration of the warranty period the main box can be folded flat for storage If you need to make ...

Page 5: ...5 13 PRODUCT DIAGRAM ACCESSORIES ITEM DESCRIPTION QTY EXHAUST HOSE 1 HOSE FUNNELL ATTACHMENT 1 A1 HOSE CONNECTOR TO UNIT 1 SLIDING WINDOW KIT 1 MANUAL 1 A2 REMOTE CONTROL 1 A3 BATTERY 1 ...

Page 6: ...listed accessories are included CONTROL PANEL AND DISPLAY Button Function Power Turns the unit on off Tem Increases set temperature Tem Decreases set temperature Mode Changes the mode Speed Changes the fan speed Timer Sets timer Full Lamp Indicates water full ...

Page 7: ...ONS 1 POWER 2 MODE 3 TIMER 4 SPEED 5 TEMP 6 TEMP 7 SLEEP 8 SWING On Off switch MODE selector Hourly programming Fan speed selector Temperature selector up Temperature selector down Night operation selector Auto air flow selector ...

Page 8: ...the opening at the back of the air conditioner A5 Venting the Exhaust Air The exhaust hose should be kept as short and straight as possible so as to not restrict airflow of the exhausted air There are 3 x options with venting the exhaust air 1 You can make a hole in the wall and pass the exhaust hose through the hole in the wall this option doesn t require a window to be slightly open 2 You can pa...

Page 9: ... sliding door and adjust the length of the window kit to fit the opening Mark and cut down a single panel of the window kit if necessary 2 Place the window kit between the window and the window frame as shown in the images to the right Close the window onto the window kit to form a tight seal 3 Attach the exhaust duct adapter to the window kit Tabs located on the adapter will lock into place secur...

Page 10: ... the Mode button till the Heat Mode icon appears Press the or button to select a desired room temperature 16C 31C Press the Fan Speed button to select wind speed Dry De humidifying Mode Press the Mode button till the Dry Mode icon blinks Set the selected temperature to current room temperature minus 2 16C 31C Set the fan motor to LOW wind speed AUTO Mode According to the current room temperature t...

Page 11: ...the water container is full the unit will display FULL by means of the Water Indicator Full lamp being illuminated on the control panel until the tank is emptied To resume operation empty the water container according to the following steps 1 Turn the unit off Try not move the unit when the water container is full can cause spillage 2 Place a drain pan under the drainage port at the back of the un...

Page 12: ...properly the air filter should be cleaned once every two weeks Open the air inlet grille and take off air filter Clean the air filter with a brush brush the dust dirt off the filter If very dirty use a neutral detergent in lukewarm water and dry in the shade Put air filter back into unit close the air inlet grille Clean the Air conditioner Surface First clean the surface with a neutral detergent a...

Page 13: ... power cord into the wall outlet Is the main power supply on Re establish the main power supply Is the water container full indicator light on Empty the water container Is the timer set Change timer settings Cooling efficiency is not satisfactory Is the air inlet or outlet blocked Clear the blocking Is there any other heat source in the room Move the heat source Are the air filters dirty Clean the...