background image

Installation & Use and Care 

Instructions

 

for

:

 

SteamerGard™ 

System 

Model WT-90 

Cleveland Range, Inc. 

UNITED STATES

 

1333 East 179th St., Cleveland, Ohio 44110 
Phone: (216) 481-4900 • Telex: 98-0546

 • FAX:

 (216) 481-3782 

Toll Free: 1-800-782-0040 

(in U.S.A. only)

 

CANADA 

8251 Keele St. • Concord, Ontario, Canada L4K 1Z1 
Phone: (416) 660-4747 • FAX: (416) 660-4492 Toll 
Free: 1-800-387-3562 

(in Canada only)

 

WTS-02

 

Summary of Contents for SteamerGard System WT-90

Page 1: ...nge Inc UNITED STATES 1333 East 179th St Cleveland Ohio 44110 Phone 216 481 4900 Telex 98 0546 FAX 216 481 3782 Toll Free 1 800 782 0040 in U S A only CANADA 8251 Keele St Concord Ontario Canada L4K 1...

Page 2: ...el Illustrations 3 WT 90 System Component Illustrations 4 WT 90 Typical Installation Schematic 5 Use and Care Operation 6 SteamerGuard Remote Control Panel 6 Manual Bypass Valve 6 Tank Pressure Gauge...

Page 3: ...ompression fittings for connection to the storage tank the steam generator and a tap water supply 3 8 OD polybutylene tubing is recommended for plumbing Storage Tank The storage tank is a self contain...

Page 4: ...mer and position it to be within reach and with access to a cold water supply Carefully holding the control panel against the wall mark the four mounting hole locations that will provide a level insta...

Page 5: ...ltered for use with the SteamerGard system Consult the steamer manufacturer for alteration instructions to convert the steamer from a single teed water connection to two separate water connections one...

Page 6: ...e Fitting 1 4 11 45 2111931 10 Clear Filter Bowl 4 60 9011 RO Auto Shutoff Valve 12 47 1212419 5 Micron Prefilter 5 35 412 1 5 Clip Auto Shutoff Valve 13 47 211211 55 Cu In Carbon Prefilter 6 52 31678...

Page 7: ...Steamergard Model WT 90 Typical Installation Schematic...

Page 8: ...amerGard system to be bypassed providing untreated tap water to the steamer until repairs can be made To use the manual bypass valve turn the handle fully clockwise so that the handle points to the by...

Page 9: ...er the steamer has been in use for a while This ensures that the SteamerGard system has been in operation producing purified water Every three months perform the following NOTE The SteamerGard unit mu...

Page 10: ...n the post treatment bowl a The clear post treatment bowl allows for easy inspection of the post treatment cartridge without the need to remove the bowl If the level of cartridge material remaining is...

Reviews: