background image

Cleveland Ironworks a subsidiary of Enerco Group Inc. 

4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001 

WOOD PELLET FIRE STOVE

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Save these Instructions for future reference. 

THE AUTHORITY HAVING JURISDICTION (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE 

DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) SHOULD BE CONSULTED BEFORE INSTALLATION 

TO DETERMINE ANY NEED TO OBTAIN A PERMIT. OBSERVE ALL LOCAL BUILDING CODES.

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

Model #

PS60W

PS130W

PSBF66W

READ INSTRUCTIONS CAREFULLY:

 Please read this entire manual before installation and use of this 

pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily 

injury or even death. Do not allow anyone who has not read these instructions to assemble, light, adjust or 

operate the stove. Place instructions in a safe place for future reference.

PS60W (F500200)

PSBF66W (F500210)

Apple Store

Google Play Store

PS130W (F500205)

Summary of Contents for F500200

Page 1: ...ERMINE ANY NEED TO OBTAIN A PERMIT OBSERVE ALL LOCAL BUILDING CODES OPERATING INSTRUCTIONS AND OWNER S MANUAL Model PS60W PS130W PSBF66W READ INSTRUCTIONS CAREFULLY Please read this entire manual befo...

Page 2: ...CH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE STOVE AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE STOVE IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBL...

Page 3: ...3 04 1 38 Pellet Consumptiovn Rate High LBS HR kg HR 4 01 1 82 5 45 2 47 5 82 2 64 Automatic Mode Duration minimum hours maximum hours 42 5 15 0 62 2 23 9 62 3 11 3 Stove Efficiency 82 3 75 8 82 2 Ou...

Page 4: ...E THE FLU WITH HEADACHE DIZZINESS AND OR NAUSEA IF YOU HAVE THESE SIGNS STOVE MAY NOT BE WORKING PROPERLY GET FRESH AIR AT ONCE HAVE STOVE SERVICED SOME PEOPLE PREGNANT WOMEN PERSONS WITH HEART OR LUN...

Page 5: ...pe must be at least 3 76 mm from any wall Finally the area which the wood pellet fire stove is installed shall have a floor to ceiling distance of at least 84 2134 mm FLOORING MATERIAL Floor protectio...

Page 6: ...he firepot See figure 2 or 3 Figure 2 PS60W and PS130W firepot 41 Figure 3 PSBF66W firepot A cleaning kit is also packaged which facilitates safely cleaning the firepot perforations of debris Air Inta...

Page 7: ...AL on page 5 Manufactured venting of 3 80 mm diameter of type L or PL which is listed to UL 641 ULC S609 Standard for 650 C Factory Built Chimneys or ULC ORD C441 Install per chimney manufacturer s in...

Page 8: ...Built Residential Type and Building Heating Appliance UL 103 A International Conference of Building Officials ICBO standards for solid fuel Stoves code approved masonry chimney VENT TERMINATION Instal...

Page 9: ...r channels separated from combustibles by a minimum of 6 inches 152 mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness...

Page 10: ...inch diameter rod can enter beyond 4 inches The stove must be on installed on a level surface which can support the weight of the stove The stove must be bolted to the level surface so that it permane...

Page 11: ...sed with either a UL 103HT US ULC S629 CAN listed manufactured chimney or an approved lined masonry chimney Not all manufactured chimney are UL103 HT ULC S629 listed Home centers hardware stores HVAC...

Page 12: ...se the pellet sediment debris at the bottom of the pellet container Store pellets in sacks made of environmentally neutral or biologically degradable plastic or from paper 2 3 layers similar to cement...

Page 13: ...following stages Cleaning Cycle The firepot draws dust ash remenants out Feeding Cycle Pellets will be transported from the Pellet Hopper into the fire pot by the auger This can take 5 to 15 minutes d...

Page 14: ...ove app SMART STOVE WIFI CONNECTION This stove can be monitored controlled and programmed by using the smart stove app by NHHATC which is available for iOS or android device through the app store Step...

Page 15: ...ood pellets while maintaining the desired temperature Pressing the ECO button will allow you to toggle whether a specific eco setting is enabled or to turn off the feature entirely ECO 1 The stove shu...

Page 16: ...reports in Fahrenheit display in the top right of the multi function display screen R Room temperature S Exhaust temperature P Protection Temperature Sensor Press to increase the temperature which the...

Page 17: ...every day Whichever is more frequent Ash Drawer After 50 bags of wood pellets Passageways After 100 bags of wood pellets Blower After 100 bags of wood pellets CLEANING FIRE POT PAN CAUTION IF STOVE I...

Page 18: ...any ash or debris build up Build up of debris and ash can restrict the flow of gases which will affect stove performance and failure to remove creosote may result in a dangerous chimney fire FLYASH F...

Page 19: ...into the most up and most left position of the prepared gasket gutter 5 Continue pressing the replacement gasket clockwise along the gasket gutter until it has wrapped back to where the gasket was pr...

Page 20: ...ed to the base If a low pressure is created in the firebox by a leak opening the door to the firebox a blocked flue or an unsealed ash drawer then the switch will shut the stove off as a precaution Er...

Page 21: ...quality fuel in fire pot 2 Check that the firepot is sitting in the holder correctly and that the igniter is not obstructed 3 Check that the exhaust gas temperature sensor switch beside the combustion...

Page 22: ...e is no problem the blower does not turn on until the stabilization cycle The blower does not turn on during Stabilization Cycle No power in stove or in control panel Check the power and wires Mother...

Page 23: ...he unit so that it will not start suddenly and then unblock the auger 2 Check that the auger is not blocked If it is blocked remove the cause of the jamming 3 Check that the auger screw fastening the...

Page 24: ...ted 2 Replace the 30 o C temperature switch The fire extinguishes and the power shuts off continued Requested temperature has been reached This is normal ECO mode behavior The stove will automatically...

Page 25: ...stion Fan Blower L FUSE N Igniter Auger motor Display panel Vaccum switch Exhaust sensor Protection sensor Room sensor NC NO C k NOTE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE...

Page 26: ...culation Blower 27 n a Chamber Insulation Cover 28 66613 Safety Sensor 29 n a Motherboard Fixed Plate 30 66631 Rear Cover 31 66615 Power Socket 32 66616 Room Sensor 33 66622 Silicone Rubber Sealing Ri...

Page 27: ...e Sensor 23 n a Ground Screw 24 66610 Vacuum Switch 25 66611 Silicone Tube 26 66612 Circulation Blower 27 n a Chamber Insulation Cover 28 66613 Safety Sensor NO P N DESCRIPTION 29 n a Motherboard Fixe...

Page 28: ...36 Right Side Panel 9 66622 Silicone Rubber Sealing Ring 10 66615 Power Socket 11 66637 Motherboard 12 66638 Fire Pot 13 66639 Vacuum Switch 14 66640 Igniter NO P N DESCRIPTION 15 66641 Combustion Blo...

Page 29: ...ber of your product and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full...

Reviews: