background image

260AZH REV. B 3/06 

 

 

 

This kit connects a PC to as many as 31 Combis at a maximum distance of 3280 Feet (1000 meters). The 
software can download cooking programs, record HACCP information, and monitor the networked 
Combis in real-time. This installation manual includes instructions for both RS232 and USB connections 
for a PC. Choose the connection that works best for your application and follow the instructions that 
apply. If any parts are missing from any kits, please contact Cleveland Range Service at 216-481-4900.

 

 

 

 

RS232 Correct connection of a PC to Combis using the Communication Module with RS232 Port. 

 

 

 

  

   

 

 
 
 
 

FOR RS232 connection use part number:  CPC-HACCP-MU232 

 
 

Correct connection of a PC to Combis using the Communication Module with USB Port

 
 
 
 
 

 
 

 

 
 
 
 
 

FOR USB connection use part number:  CPC-HACCP-MUUSB 

 

 

CAUTION 

Turn off all power to Combis before installation of PC-HACCP Network. 

Follow all Safety and Operating Instructions 

Failure to do so can result in injury, and equipment and property damage

PC-Control / HACCP Network Installation 

For Convotherm by Cleveland Combination Oven Steamers

 

1333 East 179

th

 Street 

Cleveland, Ohio 44110 
Phone: (216) 481-4900 
Fax: (216) 481 3782

 

www.clevelandrange.com 

 

Summary of Contents for Convotherm HACCP

Page 1: ...eland Range Service at 216 481 4900 RS232CorrectconnectionofaPCtoCombisusingtheCommunicationModulewithRS232Port FOR RS232 connection use part number CPC HACCP MU232 CorrectconnectionofaPCtoCombisusing...

Page 2: ...ns Failure to do so can result in injury and equipment and property damage Software CD See Page 20 for Installation Instructions USB Cable USB Adapter Photo 2 6 NOTICE In addition to the kit the follo...

Page 3: ...Connector 1 C5002091 3 Bracket with Studs 1 C2114799 4 Control Panel Spacers 2 C8009030 5 Screws M3 2 111633 6 Lock Washers 2 C8016001 7 Hexagon Nuts M3 4 C8004012 PHOTO 3 RS485 Communication Module...

Page 4: ...d 6 show the correct cable connections from the PC to the PC Converter for RS232 Note the position of the Dongle on the PC in Photo 5 Make sure the PC Converter is connected to the 9 volt DC power sup...

Page 5: ...ACK WIRE GROUND GROUND OR SHIELD WIRE RS232 CABLE CONNECTION FOR CONVERTER TO RS485 ONLY Photo 8 shows the cable connections for the PC Converter The PC Converter wiring is connected to the FIRST Comb...

Page 6: ...are and software installation and setup The USB software must be installed on the PC before using the USB adapter Photos 9 10 and 11 shows the correct USB cable connections from the PC to the Converte...

Page 7: ...emove the Control Side Cover Turn the 1 4 turn quick locks to loosen From the bottom edge of the side panel push up and pull out Remove the side panel and set it aside Photo 13 Photo 16 Photo 15 Photo...

Page 8: ...remove the Operation Panel retention screw Photo 18 Remove the Operation Panel out from the rear Be careful not to drop it Disconnect the computer cable from the Operation Panel and set the panel asid...

Page 9: ...odule 1 Mount the board to the panel using the spacers nuts and washers included in the kit Photo 20 Photo 21 Press the Communication Module Interface onto the Control Module Tighten the screws holdin...

Page 10: ...e Base Plate to the Communication Module Mount the board to the panel using the spacers and nuts included in the kit Photo 24 Complete Assembly of Communication Module Interface and Control Module Pho...

Page 11: ...tary seal plug from the underside of the Combi Photo 31 Insert the new bushing P N 111751 into the opening Pull the Communication Module cable through the Bushing Pull enough wire through the bottom o...

Page 12: ...the other end to connection B on the Communication Module Connect drain shield as ground For USB Attach the network wire to connection 2 on the Converter and attach the other end to connection A on th...

Page 13: ...ombi and all Combis in the Network To set the jumpers gently pull them from the board and install them as shown Photo 28 Wire Connection and jumpers positions for last communication module in the Netw...

Page 14: ...36 Photo 35 Place Control Board and Module back into the Combi Use wire ties to secure cable away from high voltage sharp corners and edges and moving parts Make sure the Control Board can still be r...

Page 15: ...15 Replace the Operation Panel Photo 36 Remount the Operation Panel back into the Combi Photo 37 Press down and turn clockwise to tighten the Operation Panel retention screw...

Page 16: ...the Control Side Panel Photo 38 Photo 39 Push up and in from the bottom edge of the side panel Photo 40 Photo 41 Turn the 1 4 turn quick locks to tighten See the PC HACCP Instructions to use the PC HA...

Page 17: ...the kit 3 Follow the instructions that are on the CD to configure the COM ports so the computer can recognize the USB adapter See configuration pages for data speeds and other settings 4 Configure the...

Page 18: ...18 Select install from a list of specific location advanced Ignore this screen if it appears...

Page 19: ...19 Uncheck Include this location in the search Click Next Let search...

Page 20: ...20 The Hardware wizard will appear a second time...

Page 21: ...21 Follow the directions in each screen...

Page 22: ...22 Allow search for CD...

Page 23: ...23 Click Finish to close the screen Configure your serial device 1 Right click My Computer select properties Then select the Hardware tab and click on the Device Manager button...

Page 24: ...24 Expand the Ports COM LPT device...

Page 25: ...25 Right click on the USB Serial Port COM item The will be a number greater than 0 and less than 255 Select the Port Settings tab...

Page 26: ...26 Note the COM setting Only COM1 COM2 COM3 and COM4 can be used by the HACCP software To change the COM number click the Advanced button...

Page 27: ...7 If needed click the COM Port Number drop menu and select and acceptable port number If all are marked as in use then change one of the other serial devices to a COM port number higher than 4 Click O...

Page 28: ...ON For USB to RS232 Switches 2 3 4 are ON 6 Once the computer recognizes the USB adapter the dip switches in the adapter have to be set up for RS485 or RS232 data transfer chose the correct setting t...

Page 29: ...r RS485 a jumper inside the metal case must be positioned correctly This photo shows the position of the 1 jumper All other jumpers should be in the original position 8 Place the metal cover back on t...

Page 30: ...Not for Printing Cleveland Range LLC 1333 East 179th St Cleveland Ohio 44110 Drawing No 260AZH Revision Index Page REV REVISION HISTORY DATE BY A 260AZH Production Release Per EO C 6947 12 12 05 ERB B...