1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110 

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]  

 

CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE

MODEL

c

36-CSM

Cleveland Standard Features

n

Cooking Capacity for up to six 12˝ x 20˝ x 2

1

2

˝ deep Cafeteria Pans.

n

Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.

n

Solid State Controls operate water level and safety functions.

n

Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.

n

Instant Steam Standby Mode:

Holds generator at steaming

temperature. Allows unit to start cooking instantly.

n

Durable 14 Gauge Stainless Steel Construction:

For Compartment Door and Steam Cooking Cavity.

n

Separate Main Power Switch for “On/Off”

n

Exclusive Steam Cooking Distribution System:

The exclu-

sive Convection Jets produce a high velocity convection steam
without fans. Coved Corner design in cooking compartment distrib-
utes heat evenly and is easy to keep clean. Creased top & bottom
enhance drainage. Cold Water Condenser for each compartment
maintains a dry steam. Fully insulated cooking compartment for
thermal efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.

n

Exclusive “Cool to the Touch” Compartment Door Design:

Free floating inner door with reversible door gasket provides
an air tight seal. Stainless Steel Slam/Latch Door Latch
mechanism provides greater reliability.

n

Left Hand Door Hinging:

Compartment Doors hinged left,

controls on the right.

n

Modular Cabinet Base with Hinged Door.

n

Steam Coil Generator:

Automatic Water Fill on start up.

Minimum 35 psi incoming steam pressure required with a 

3

4

˝ steam line.

n

Automatic Generator Drain at shutdown:

Contains a “Water

Jet” Spray Rinse Cleaning Cycle to keep drain clear.

n

Automatic Water Level Control System 

with Low Water

Power Cut-off Circuit.

n

Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.

n

Secondary Low Water Cut-Off, factory installed (CALS)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.

MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash.

DC)

n

NSF Certified 6˝ Stainless Steel Legs

with adjustable

flanged feet for a one inch level adjustment.

n

Standard Voltage for Controls: 115 volts, 60 Hz, single phase.

n

All Controls are serviceable from the front.

Shall be Two Compartments, CLEVELAND Convection Steamer, Model 36-

CSM, Steam Coil Steam Generator, 115 volts, single phase. Solid State

Controls operate timing, water level and safety functions. Steam Generator

with Automatic Water Fill on start-up and Automatic Blowdown with additional

Manual Drain Valve. For each cooking compartment: 60 minute Mechanical

Timer, Manual Operation Mode and Cold Water Condenser. Type 304 Stainless

Steel cooking compartment.

Options & Accessories

p

Right Hand Door Hinging, Controls on the Left (DHR)

p

Electronic Timer with Compensating Load Feature (ETC)

p

Compartment Door Steam Shut Off Switch (SCS)

p

ON/OFF Steam Switch only for compartment controls (MC)

p

Cafeteria pans in depths of 1˝, 2

1

2

˝, 4˝ and 6˝

p

Additional Power Reducing Valve (PRV)

p

Moisture Separator Trap (MS)

p

Stainless Steel Base Frame (FSS)

p

Correctional Packages

p

Boiler Descaling Pump Kit (107142)

p

Water Filters

Short Form Specifications

Shown with optional

Electronic Timer

Cleveland Classic Series

TWO  COMPARTMENT, PRESSURELESS
STEAM COIL GENERATOR
36” WIDE CABINET BASE DESIGN

CONVECTION
STEAMERS

SECT.

III

PAGE 

13

0707