Cleveland Standard Features

n

Factory assembled Kettle/Steam Generator NickleGard
Base combination with one 3 gallon and one 6 gallon kettle
with 200M BTU Gas-Fired Steam Generator

n

Solid State steam generator Water Level Controls

n

Low Water Safety Cut-Off

n

Pressure Limit Controls with 15 psi Safety Valve

n

Type 430 Stainless Steel exterior enclosure, and table top
(with Drain Trough which has 1.50" diameter male drain), 
#4 exterior finish

n

Type 304 Stainless kettle(s), #4 exterior finish

n

Separate "Start/Reset" Illuminated Switch Controls, plus
Pressure Gauge

n

Solid State Electronic Spark Ignition for energy savings

n

Major components serviceable from the front of the unit

n

Kettle(s) are 2/3 Steam Jacket rating, and include Lift-off
Covers

n

Hot and Cold Water Faucet with Swing Spout

n

Kettle(s) have 50 psi Steam Jacket Rating, 50 psi chrome
plated Safety Valve(s) and Manual Tilting, balanced design

n

Tilt Handles can be mounted on either side

n

Steam Generator empties under pressure (blowdown) 
automatically upon each Shut-Down. Automatic Water 
Refill on Start-Up

n

Standard voltage for controls is 115 volt, 60 Hz, single
phase

n

Adjustable Flanged Feet (FF-A)

Options & Accessories

p

Power Take-Off Kit (GPTO)

p

Secondary Low Water Cut-Off, factory installed (CALG)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI.

MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,

Wash. DC)

p

Gas, other than natural

p

Type 316 Stainless Steel kettle interior for high acid food
products (316)

p

Food Strainers (FS)

p

Stainless Steel Base Frame (FSS)

p

300,000 BTU Gas-Fired Boiler with Nickelguard

p

Boiler Descaling Pump Kit (107142)

Shall be CLEVELAND, Modular Cabinet Base with one 3 gallon and one 6

gallon kettle, Model 36-GM-K36-200, 200M Nickelguard BTU Gas-Fired

Steam Generator, type 430 Stainless Steel exterior enclosure, Table Top,

Back Splash and 4 level adjustable feet. 2/3 Steam Jacketed type 304

Stainless Steel kettle(s) with 50 psi Steam Jacket Rating; needle type Steam

Control Valve on each kettle. Console mounted Controls, Pressure Gauge

and Illuminated "Start/Reset" Control Switches. Solid State Water Level Steam

Generator Controls and Electronic Spark Ignition. Steam Generator drains

under pressure (blowdown) after each Shut-Down with Automatic Water

Refill on Start-Up. 15 psi Safety Valve

Short Form Specifications

SECT.

VII

PAGE 

25

1106

MODULAR BASE WITH KETTLES

200M BTU GAS-FIRED STEAM GENERATOR with NICKELGUARD™
ONE 3 GALLON KETTLE AND ONE 6 GALLON KETTLE
CABINET BASE: 36" (900MM) WIDE

1

0

0

%

5

Ye

ar Boiler

W

a

rr

a

n

ty

N

ic

ke

lGuar

d

Cleveland

Project  ________________________________

Item  __________________________________

Quantity  _______________________________  

FCSI Section  ____________________________

Approval  _______________________________

Date  __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110 

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]  

 

MODULAR BASES

Reviews: