LCD
The operating menu on the socket tray is divided into a
main menu and submenus. You can navigate through the
menus using the two function keys below the LCD display.
In the following description, <F1> is used for the left func-
tion key and <F2> is used for the right function key. The
menu is activated by pressing the right function key <F2>.
Basic functions
•
<F2>: Activate main menu.
•
<F1>: Go to previous menu item.
•
<F2>: Go to next menu item.
•
Press <F1> for longer than two seconds to go to the
next higher menu level.
•
Press <F2> for two seconds to go to a submenu.
•
Press the on/off switch: The highlighted entry is acti-
vated, or the highlighted activity is executed.
•
When the menu is active, the initiators on the inserts
do not respond to changes if the sockets are added or
removed.
•
At the end of each submenu there is an entry for
Back
.
7.1 Main function
After the initialization phase, the connection status to the
nutrunner control and the operating status are displayed.
The connection status can be:
•
Waiting for connection
: Still no connection to a nut-
runner control after switching on. Nothing is indicated
by the status LEDs and no initiator status is evaluated.
•
Connection
: A connection to a nutrunner control
exists. The connection controls the status of the
status LEDs and evaluates the status of the initiators.
•
Connection lost
: A connection to a nutrunner control
exists. However, the nutrunner control has not commu-
nicated with the socket tray again within the pro-
grammed time. This is indicated by alternating
status LEDs flashing on the inserts of the sockets.
The display changes automatically between the connection
status display
Init.
and the operating status
Power
. Func-
tion keys <F1> and <F2> under the LCD can be used to
change between the connection status display and the
operating status. After a button is pressed, the display
freezes for five seconds and then automatically changes
again.
The connection status is also indicated by the green LED
display above the LCD. This lights up continually when a
connection is present.
The operating status is indicated by the red LED display
above the LCD. These flash if a fault is present. A fault
here is either an initialization failure or a warning about the
operating voltage or battery voltage.
7.2 Structure
Activates the main menu.
Back
Main menu
Administration
Diagnostics
Administration
LMC
Serial number
Wireless transmission
Software version
Back
Hardware configura-
tion
Back
Diagnostics
Voltages
LED test
Initiator test
Extension board test
Back
LMC
MAC address
Serial number
Country code
Back
Wireless WLAN
Wireless module
version
MAC address
IP address
Subnet
Gateway
Host
SSID
BSSID
Signal strength
Roaming
Transmission output
Bands
Channel used
Channels scanned
Baud rate
UDP/TCP communi-
cation protocol