5.4 Updating the firmware
Update the firmware using the
LiveWire RF Settings
pro-
gram.
1. Select the
Tool Identification
tab.
2. Press <Update Info> to check whether a correct con-
nection is possible.
3. To select suitable software, press <Software Update>.
Make sure that firmware suitable for the socket tray is
selected. This has the ending
.tma
and the name
starts with
S169280
.
4. Confirm the update process.
→ During the firmware update, the red and green LED
display on the socket tray flashes and
Softw
update
appears on the LCD.
Fig. 5-5: Tool identification tab — software update
Once the update is complete,
Update OFF
appears on the
LCD and the socket tray is automatically switched off.
The firmware is only temporarily stored during the down-
load. The boot loader does not therefore flash-save the
firmware until the next time the socket tray is switched on.
For this reason, the switch-on process takes a little longer
(about five seconds) the first time it is switched on after the
firmware download.
When the firmware has been flash-stored, the red and
green LED display flash.
After flash-storing, the boot loader automatically starts the
firmware and the normal starting procedure takes place.
5.5 Connecting to a nutrunner control
system
The nutrunner control allows the connection to the socket
tray. The corresponding steps are described in the pro-
gramming manual of the respective software.
If a connection is set up after switching on, the socket tray
will expect a connection to be regularly set up by the nut-
runner control.
The LEDs indicate whether the socket tray is connected to
the nutrunner control:
•
Green LED display lit up: Connection set up.
•
Red status LEDs on the inserts for the sockets flash-
ing: No connection could be set up within a pro-
grammed time.
Conn. lost
appears on the LCD. To fix
the connection problem see chapter
.
•
If a connection is interrupted and set up again, the pre-
vious status of the status LEDs on the inserts of the
sockets is restored and
Conn. set up
is displayed on
the LCD.