Menus and Functions
16
P2398PM |
2019-12
Apex Tool Group
3
EN
Display of the rundown data
Selecting the Linking group
To change between the FastApps, press
or
.
→
Only Linking groups that have already been parameterized can be selected.
→
A new display appears with the following selection options:
If the FastApp is blocked
(under:
>
>
), then the selection options are not available.
In this case, a PIN must be entered to switch to another Linking group. A requirement is that a PIN has been
defined in the PIN menu (
>
>
).
Symbol
Description
Batch display
Number of tightening positions for a FastApp.
•
If there is only one FastApp, then each result is evaluated.
•
If there is more than one FastApp, the overall result of all the tightening positions
is considered.
Example: 2/3
•
Current tightening position: 2
•
Total number of tightening positions: 3
Display of the torque for the current tightening.
If an arrow pointing up appears next to the symbol, the result is too high.
If an arrow pointing down appears next to the symbol, the result is too low.
Display of the angle for the current tightening.
If an arrow pointing up appears next to the symbol, the result is too high.
If an arrow pointing down appears next to the symbol, the result is too low.
Indicates that the node number or IP address of the tool is assigned twice.
Change the node number or IP address.
Button
Description
Press the
button to select a new Linking group.
must be pressed to cancel the process and return to the run screen
Summary of Contents for CellCore CCBA
Page 65: ......