background image

Vacuum-ultraviolet Ozone Systems

TM

Ozone

MAX

3

Model

OZ-SPA

Installation 

Operation Manual

Summary of Contents for OzoneMax OZ-SPA

Page 1: ...Vacuum ultraviolet Ozone Systems TM OzoneMAX 3 Model OZ SPA Installation Operation Manual ...

Page 2: ...d immediately If electrically connecting this unit directly to pool controls ensure the controls are protected by a G F C I Ground Fault Circuit Interrupter Install at least five 5 feet from wall of pool water using nonmetallic plumbing Install ozone generator no less than one 1 foot above the maximum water level to prevent water from contacting electrical equipment Install in accordance with the ...

Page 3: ...from a body of water Bullet Level Drill Drill Bits Hacksaw or Pipe Cutter PVC Cement PVC Cleaner Primer Utility Knife Screwdrivers Flat Phillips Screws Anchors within 6 feet within 6 feet Power Source TimerBox OZ SPA Unit Venturi Injector E Installing the Power Box Mount the OZ SPA unit to a post or wall using the four mounting screw holes in the enclosure base The unit may be mounted horizontally...

Page 4: ... supplied power only when the power is supplied to the pool filter circulation pump A permanent ground bonding connector is provided on this unit and should be used to connect a minimum 12 AWG solid copper wire conductor to any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within five 5 feet of the unit G Installing the Venturi Injector Using the above drawin...

Page 5: ...important that you install the Kynar check valve where air flow is allowed toward the injector Air direction can be tested by blowing into the I D polybraid tubing If correctly installed you will see air bubbles enter the I D clear vinyl tubing DO NOT SUCK ON THE I D TUBING WHEN CONNECTED TO THE OZONE SYSTEM After installation and turning on all the equipment you will see a frothing very tiny milk...

Page 6: ...is functioned correctly Turn the system on temporarily if needed The indicator light located next to the output connector will glow a nice blue color The ozone unit should only be on when the pump is running To insure that the venturi injector and bypass are working correctly simply observe to see if small bubbles are entering the pool and the frothing effect is taking place in the clear window of...

Page 7: ... from the wall This is to insure you carefully remove the delicate equipment from the metal enclosure properly and seal back up tightly Replacing the bulb in the OZ SPA unit 1 Disconnect power from the OZ SPA unit Coming into contact of the exposed ozone bulb can cause serious damage to your health 2 Remove the six 6 screws on the bottom of the unit Continue on next page J Periodic Inspection cont...

Page 8: ...ce inside the unit There is no need to add another zip tie as this was used for shipping purposes 8 Replace the bottom plate making sure the gasket is seated in the groves properly 9 Tighten the 6 screws back into place securing the bottom plate tightly 10 Reconnect power Make sure the bulb indicator the clear connector on the output tube of the power box glows in a blue color Again you may want t...

Reviews: