ClearOne 910-001-013-W Installation Manual Download Page 11

Technical Support: 800.283.5936

Software Setup of the Ceiling Microphone Array

The Ceiling Microphone Array can be used with the ClearOne Converge Pro, Interact Pro, and 
Interact AT audio conferencing mixers. Each Ceiling Microphone Array requires 3 microphone 
inputs. 

Attention Installers:

 You must apply the software setup and filter settings in the 

audio conferencing mixer to obtain the best performance from the ClearOne Ceiling 
Microphone Array. Failure to apply these filter settings will result in degraded audio 
performance.

CONVERGE PRO MICROPHONE ARRAY SETUP

1.  With Converge Console connect to the Converge Pro. 
2.  In Converge Console go to the channel view for the first microphone input. 
3.  Verify 

PPWR

 (Phantom Power) is turned on.  The Ceiling Microphone requires phantom 

power for operation. 

4.  As a starting point set the 

Coarse Gain

 to 50 dB and the 

Fine Gain

 to 0 dB.  Depending 

on your application and the user to microphone distance, the gain settings may need to 
be adjusted.

5.  Click on the 

NC button

 and 

Enable Noise Canceller

. Set the 

Cancellation Depth

 to 6 

dB. This can be adjusted, if desired, based on your application.

Summary of Contents for 910-001-013-W

Page 1: ...PDF provided by Conference Room AV ClearOne 910 001 013W Ceiling Microphone Array Kit White...

Page 2: ...Ceiling Microphone Array INSTALLATION MANUAL...

Page 3: ......

Page 4: ...unting 2 Cables 2 Pass through Mounting Assembly 3 Tools Required 3 Determining the Placement 3 Installing the Microphone Array 4 SOFTWARE SETUP OF THE CEILING MICROPHONE ARRAY 7 Converge Pro Micropho...

Page 5: ...to a single unit array providing the rich sound of three individual unidirectional microphones while maintaining full 360 degree coverage The design minimizes noise pickup from sources near the ceilin...

Page 6: ...are provided allowing you to use the most suitable length A grommet is included to cover where the cable connects to the pass through mounting assembly One 25 foot RJ45 Male to RJ45 Male CAT5e cable i...

Page 7: ...e characteristics of the room where it will be installed and the pickup pattern of the microphone array The choice of either the 12 or 24 inch microphone cable determines how close the microphone arra...

Page 8: ...rough each removed ceiling tile where the pass through Mounting Assembly will be placed Drill 1 Inch Hole for Placement of Mounting Assembly 4 Insert the Mounting Assembly through the hole with the RJ...

Page 9: ...6 Make sure the mini XLR cable is fed through the grommet Connect the mini XLR connector into the receiving plug at the bottom of the Mounting Assembly then slide the Grommet over the cable and conne...

Page 10: ...5 to XLR M adapter is for the Interact Pro and Interact AT mixers 9 Connect the CAT5e cable from the Ceiling Microphone Array to the adapter cable ordered to match the microphone inputs on the mixer N...

Page 11: ...ly these filter settings will result in degraded audio performance CONVERGE PRO MICROPHONE ARRAY SETUP 1 With Converge Console connect to the Converge Pro 2 In Converge Console go to the channel view...

Page 12: ...gain of 5 dB and a Q of 0 40 Filter 2 is a PEQ filter with the center frequency at 4000 Hz with a gain of 2 dB and a Q of 0 27 Filter 3 is a Low Pass filter set at 12000 Hz 8 Other settings in the mic...

Page 13: ...and the Fine Gain to 1 dB Depending on your application and the user to microphone distance the gain settings may need to be adjusted 5 Click on the Processing Tab 6 Enable the NC button and set the...

Page 14: ...INSTALLATION MANUAL 10 9 Other settings in the Microphone Settings screen can be set or adjusted based on your application 10 Repeat the filter setup for the other 2 Ceiling Microphone Array inputs...

Page 15: ...and the Fine Gain to 1 dB Depending on your application and the user to microphone distance the gain settings may need to be adjusted 5 Click on the Processing Tab 6 Enable the NC button and set the C...

Page 16: ...INSTALLATION MANUAL 12 9 Other settings in the Microphone Settings screen can be set or adjusted based on your application 10 Repeat the filter setup for the other 2 Ceiling Microphone Array inputs...

Page 17: ...ily recyclable materials such as aluminum and steel ELECTRICAL SAFETY ADVISORY This equipment uses DC power supplied from an external source which can be subjected to electrical surges typically light...

Page 18: ...turns require a Return Material Authorization RMA number Contact ClearOne Technical Support before returning your product Make sure you return all the items and packing materials that originally shipp...

Page 19: ...013 Jan 9 2012 Rev 1 3 2012 ClearOne All rights reserved No part of this document may be reproduced in any form or by any means without written permission from ClearOne ClearOne reserves specific priv...

Page 20: ......

Page 21: ...ClearOne 5225 Wiley Post Way Suite 500 Salt Lake City UT 84116 Telephone 1 800 283 5936 1 801 974 3760 FAX 1 801 974 3669 E mail tech support clearone com On the Web www clearone com...

Reviews: