51
FieldSmart
®
Fiber Active Cabinet (FAC) 900
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 020420 REV B - April 2019
Conduit Locations
(as viewed from bottom)
Wall/H-Frame Mounting Guidelines
When installing the wall/H-frame mount kit, observe the following guidelines. Refer to the
wall/H-frame configurations and
drawings
for guidance.
Guidelines
Follow these guidelines to ensure proper mounting support for the cabinet and EXM. Adjust for local conditions or practices
as required.
• The wall/H-frame must be vertically plumb.
• The wall/H-Frame must support a minimum load weight, as follows:
• FAC 900 only:
730 lbs
• FAC 900 + EXM:
880 lbs
Note:
These weights include fully loaded enclosures, with a single battery string.
• The top of the base platform must be a minimum of 15.25 inches above the ground.
•
The wall or H-frame must stand a minimum height above the ground, as required for the cabinet mounting configuration:
•
Low profile configurations:
The wall or H-frame must stand at least 66 inches above ground.
•
High profile configurations:
The wall or H-frame must stand at least 76.835 inches above ground.