22 CV1800 and CVMAX Installation Guide
© Clear Vue Cyclones 2018
Installing the Filter Stack Assembly
(filtered systems only)
1. Slide the filter stack assembly under the 90° filter transition. The fit should be exact.
If you purchased our Filter Clean Out Box with your system, its height can be adjusted
from 5-¾” – 7-½” by extending the three ¼”-20 bolts on the bottom.
If you are installing your system higher than 96”, the filter stack assembly
will need to be supported from below.
2. Secure the filter stack assembly to the 90° filter transition end plate:
a. Drill (3) pilot holes in the MDF and attach the filter stack assembly using (3) 1-¼” #6
sheetrock screws.
These screws are not meant to be load-bearing in any way. They are intended to keep
the connection secure if the filter stack is accidentally bumped.
b. Run a bead of clear silicone caulk around the seam where the 90° filter transition end
plate meets the top filter.
3. If you purchased a Filter Clean Out Box from us, caulk the seams where the PETG wrapper
meets the MDF top and bottom.
Completed Filter Stack Assembly