P S - 7 0 2 T W O - C H A N N E L P O W E R S U P P L Y
2 - 2
LINE TERMINATION (REAR PANEL)
Switching of the channels’ terminations
on
and
off
is done with the rear-panel
toggle switches. In most systems, all terminations on the PS-702 should be in
the
on
position (default setting). The fundamental concept of Clear-Com
party-line intercom is that all channels are terminated in one location,
preferably at the power supply.
Caution: All intercom lines must be terminated. Care must be taken not to
“double-terminate” a line. All unused intercom lines must also be
terminated.
The PS-702 provides terminations for each of its two channels. Clear-Com
main stations and power supplies provide switch-selectable termination
networks on all intercom lines. It is up to the user to ensure that the
terminations are set correctly. An unterminated line will cause excessive
levels, possible oscillation of line drivers, and severe imbalance of hybrid null
networks. A line with double or multiple terminations will cause low levels
and severe imbalance of hybrid null circuits.
If the PS-702 is the only power supply in the system (no other power supplies
or powered main stations are in the system) the termination switch on each
channel of the PS-702 should be switched to
on
. Simply toggle the rear-panel
switch labeled
term
to the
on
position. The termination switch should be set to
the
off
position
only
if the channel is terminated at another station.
PROGRAM INPUT (REAR PANEL)
An XLR connector provides the main program input to the station. This input
level is controlled by the rear-panel
program trim
control adjacent to the
program input
connector. This control sets the overall level for all of the
channels. The input accepts a balanced or unbalanced line-level audio signal.
The program can be fed to either or both of the intercom lines by using the
front-panel toggle switches labeled
program
on/off
. There is one of these
switches for each channel.
The pinout of the
program input
connector is as follows:
Pin 1--- Ground (shield)
Pin 2 --- - Signal
Pin 3--- +Signal
RACK MOUNTING
The unit requires 1.75 in. (4.45 cm or 1RU) of rack space. It requires no
additional free rack space above or below it for ventilation. The station is 5.25
in. (13.34 cm) in depth and requires at least 2.5 in. (6.35 cm) clearance in the
rear for connectors and cables. The single-piece front panel has integral “rack
ears.” This adds stability and strength.