Eclipse
|
Upgrade Guide
Page 139
1.
Ensure that you have the required equipment:
•
2 MBit PROM device (
ST M27W201
or equivalent).
•
PROM programming unit and PROM programming software appropriate for that unit.
•
Appropriate ‘
S
’ record file. To find the file, go to:
Drivers USB > ECLIPSE DRIVERS > Omega-Median-Delta > xxxxxx
– E-Que MKI
(Green PCB) Boot ROM
(where
xxxxxx
represents the part number).
.
The folder contains the
*.s
record file and a
Read Me
file (
*.txt
), with version
information.
2.
Ensure that the PROM device to be programmed is empty.
3.
Program the PROM device with the appropriate file, according to the instructions
for the PROM programmer being used.
Note:
The load address for the
S
record is
0xFFF00000
.
Confirm that the checksum of the programmed device matches that detailed in
the Eclipse HX Release Notes.
4.
Remove the existing PROM device from the configuration card.
Insert the newly programmed PROM device taking care to ensure the correct
polarity of the device.
Observe all electrical shock hazard warning and precautions for
handling electrostatic sensitive devices
9.6
Upgrading the E-QUE card (MK2) boot ROM
Only upgrade the E-QUE (MK2) boot ROM after the main E-QUE application code has
been upgraded.
Note:
The procedure below is for E-QUE (MK2) cards only. To upgrade the PROM of an E-QUE
card (MK2), see
9.5 Upgrading the E-QUE card (MK1) boot
To upgrade the E-QUE (MK2) boot PROM:
1.
Ensure that you have the following equipment:
Required equipment
Description / comments
Tera Term software
Tera Term must be configured and operational.
You can find the Tera Term application on both
of the Eclipse HX 9.0 upgrade media:
Software USB > SOFTWARE - EHX.xxx >
3rd_Party_Software > Teraterm
Drivers USB > ECLIPSE DRIVERS >
3rd_Party_Software > Teraterm