Cleanlife GDM26 Instructions Download Page 1

KIT No. CL-RYV-K-1 

INSTRUCTIONS FOR SINGLE-DOOR GDM26 COOLER

Please Follow the steps below for installation of the 
CLEANLIFE

®

 SINGLE-DOOR COOLER Retrofit Kit.

Thank you for purchasing the CLEANLIFE

®

SINGLE-DOOR COOLER RETROFIT KIT.

1 x CL-CTS24SD19H32N-48N

Tools Required for Installation: Phillips head screwdriver or driver, hex 
head driver, wire stripper, wire cutter, wire nuts & zip-ties.

SAFETY WARNING:

Prior to installation, verify that power has been disconnected 
from the system!
Use all necessary precautions while performing this procedure.

Remove the lamp socket panel from the cooler to gain access 

to the lamp socket wiring (Blue and Red wire). The panel, 

sockets, and T8 fluorescent bulb can be disposed of once 

removed. Ensure the fluorescen  bulb is properly disposed of.     

Remove the top and bottom lamp socket from the door and cut the wiring going to both sockets to allow the 

IDL harness to be completely removed from the door frame. All components removed can be disposed of.  

Remove the 

top sign 

frame header 

from the 

cooler to 

gain access 

to the top T8 

fluorescent 

bulb and 

lamp sockets.

Using two WAGO connecters (2 way 

connector) connect the 24" Frosted 

LED strip to the cabinet harnessing. Red 

to Red and Black to Blue.

1 x CL-CTS24SD12J00N-48N

2 x CL-A-7

6 x CL-A-13

1 x CL-CTS24FD00N06N-24N

1 x WIRE COVER FOR GDM26

1 x IDL COVER

1 x LPV-20-24

4 x 2 Way WAGO 

     Connectors

2 x ZINC-PLATED 

     SCREWS (#4-1/2")

2 x 3 Way WAGO 

     Connectors

Step 1:

 

Step 2:

 

Step 3:

 

Step 4:

 

Step 7:

 

Remove and properly 

dispose of the lamp 

shield and T8 fluorescent 

bulb from the inside of 

the door.   

Step 6:

 

Step 5:

 

Step 8:

 

Insert the right side LED strip into the mounting clip 

(handle side) but do not secure to the frame until you 

have the left side installed.    

Step 9:

 

THIS KIT INCLUDES: 

8 x BLACK SCREWS 

     (#8-3/8")

Attach the two LED strip 

mounting clips (CL-A-13)  

to the header panel so 

that the clips will attach 

to the LED approximately 

2" from each end of the 

LED Strip. 

3 x ZINC-PLATED 

     DRILLING SCREWS 

     (#8-1 1/2")

Cut the Blue and Red wires to 

length after LED is mounted. 

Using the zinc-plated screw 

(4-1/2"), attach the middle LED 

strip mounting clip (CL-A-7) to 

the right door frame (handle 

side) aligning so it is half way up 

the glass, then attach two end 

mounting clips (CL-A-13) to 

secure the LED strip. Repeat this 

process when installing the clip 

to the new IDL cover. You will 

want the clips to be in the same 

line as each other then you 

open the door.  