![Cleanlife GDM26 Instructions Download Page 1](http://html1.mh-extra.com/html/cleanlife/gdm26/gdm26_instructions_2620319001.webp)
KIT No. CL-RYV-K-1
INSTRUCTIONS FOR SINGLE-DOOR GDM26 COOLER
Please Follow the steps below for installation of the
CLEANLIFE
®
SINGLE-DOOR COOLER Retrofit Kit.
Thank you for purchasing the CLEANLIFE
®
SINGLE-DOOR COOLER RETROFIT KIT.
1 x CL-CTS24SD19H32N-48N
Tools Required for Installation: Phillips head screwdriver or driver, hex
head driver, wire stripper, wire cutter, wire nuts & zip-ties.
SAFETY WARNING:
Prior to installation, verify that power has been disconnected
from the system!
Use all necessary precautions while performing this procedure.
Remove the lamp socket panel from the cooler to gain access
to the lamp socket wiring (Blue and Red wire). The panel,
sockets, and T8 fluorescent bulb can be disposed of once
removed. Ensure the fluorescen bulb is properly disposed of.
Remove the top and bottom lamp socket from the door and cut the wiring going to both sockets to allow the
IDL harness to be completely removed from the door frame. All components removed can be disposed of.
Remove the
top sign
frame header
from the
cooler to
gain access
to the top T8
fluorescent
bulb and
lamp sockets.
Using two WAGO connecters (2 way
connector) connect the 24" Frosted
LED strip to the cabinet harnessing. Red
to Red and Black to Blue.
1 x CL-CTS24SD12J00N-48N
2 x CL-A-7
6 x CL-A-13
1 x CL-CTS24FD00N06N-24N
1 x WIRE COVER FOR GDM26
1 x IDL COVER
1 x LPV-20-24
4 x 2 Way WAGO
Connectors
2 x ZINC-PLATED
SCREWS (#4-1/2")
2 x 3 Way WAGO
Connectors
Step 1:
Step 2:
Step 3:
Step 4:
Step 7:
Remove and properly
dispose of the lamp
shield and T8 fluorescent
bulb from the inside of
the door.
Step 6:
Step 5:
Step 8:
Insert the right side LED strip into the mounting clip
(handle side) but do not secure to the frame until you
have the left side installed.
Step 9:
THIS KIT INCLUDES:
8 x BLACK SCREWS
(#8-3/8")
Attach the two LED strip
mounting clips (CL-A-13)
to the header panel so
that the clips will attach
to the LED approximately
2" from each end of the
LED Strip.
3 x ZINC-PLATED
DRILLING SCREWS
(#8-1 1/2")
Cut the Blue and Red wires to
length after LED is mounted.
Using the zinc-plated screw
(4-1/2"), attach the middle LED
strip mounting clip (CL-A-7) to
the right door frame (handle
side) aligning so it is half way up
the glass, then attach two end
mounting clips (CL-A-13) to
secure the LED strip. Repeat this
process when installing the clip
to the new IDL cover. You will
want the clips to be in the same
line as each other then you
open the door.