Pro Ox 5900-BT-AIR Installation & Startup Guide
Page 21
www.cleanwaterstore.com
Rev. 02-26-2020
Filter System Normal Operation
•
Normal display alternates between time of day and days until regeneration.
•
Days remaining until the next regeneration will count down from the regeneration day
override value to 1 day remaining. Once count reaches 1, a regeneration will be initiated at
next scheduled regen time.
How to Start A Manual Backwash
1.
If days remaining is not already at 1 press and hold the Set/Change button.
2.
After 7 seconds the days remaining display will read: [1]
3.
With days remaining at 1 press and hold the Set/Change button again.
4.
After 5 seconds the regeneration cycle will begin.
5.
Fast Cycling Through each Step: First complete above immediate cycle steps
6.
Press and hold the Set/Change button
7.
After 3 seconds the valve will start to advance to the next step
Pro-OX Air 5900-BT Maintenance
No weekly or monthly maintenance is required.
Replace the seals and spacers (see Page 27)
every 1 – 2 years. Once a year clean the air injector (see page 28) for exploded view.
If you
are using the chlorine draw feature, clean the chlorine injector (see Item 17, page 28).