4. Key panel
3. CONFIGURATION and LCD INTRODUCTION
2. Precautions
Thank you for selecting Clean products.
Before using the meter, relevant person must read and understand the contents
of this operation manual. Operation Manual should be kept accessible within
the person who use the meters.
Components:
MDH30 Tester
CS6931 sensor
Sensor soaking solution
SL6080(40ml/bottleX1)
Wiping paper
CW100
(50*25mm)x3
Battery
Instruction Manual
Set up
Data stabilized
Low battery indicator
Measurement mode
Auto Lock function
Auto Lock after data stabilized
Measuring value
ppm,mV - measuring mode, unit
Dissolved Hydrogen Meter
H
2
H
2
H
2
H
2
H
2
H
2
H
2
CLEAN INSTRUMENTS CO. LTD
2F No.140, Zhongxiao St.,
Zhonghe Dist., New Taipei City ,
Taiwan
Instruction Manual
1.Product Overview
-2-
-3-
-4-
DH30 tester
Dissolved Hydrogen meter
1.
2.
3
4.
5.
6.
7.
8.
9.
10.
11.
12.
2
3
3
4
4
5
5
6
7
7
8
8
····························································
····································································
·····················
·········································································
···································
·······················································
··········································································
······································································
··········································································
·································
················································································
··················································
ENT
SET
CAL
+
-
AAA
CAL
ENT
SET
CAL
PH30
www.cleaninst.com
Customer Service: [email protected]
Dissolved Hydrogen Meter
H
2
H
2
H
2
H
H
2
H
2
Immersion
depth:
≤
50mm
Operation
Manual
Product Overview
Precautions
CONFIGURATION and LCD INTRODUCTION
Key Panel
Battery and electrode installation
Measurement Mode
Set up
Specification
Package
Electrode using and maintenance
Error
GENERAL INFORMATION
TABLE OF CONTENTS
Long press to enter into mV mode
Increment values or scroll through the next options available
Long press to Power ON/OFF
Short press to ON/OFF backlight
Escape key when in mV mode and setting up
Data setting
Decrement values or scroll through the next options available
Confirm key
Press to unlock in Auto lock mode
5. Battery and Electrode installation
Unscrew the screw cap by following the
arrow direction, slightly unplug the
electrode, install the battery(pay attention
to the anode and cathode of the
electrode).
Then install back the electrode and the
screw cap.
Low battery prompt is at the top of the
screen when battery power is low.( You can
refer to the LCD INTRODUCTION). Please
change the same model battery.
ENT
SET
CAL
PH30
ENT
SET
CAL
PH30
AAA
+
Short press
: Short press means release the key once after pressing.
(If there is no mark out below, default it as Short press)
Long press
: Long press means press the key for 3 seconds and then release it
Hold
: Hold means not release the key and accelerate after a certain time. Not release the key
until the value is set as needed.
Key instruction
Precise and easy operation, Comfortable holding, All functions operated in one hand.
Large LCD with backlight, Multi-line display for easy reading, Auto-Power Off saves
battery after 5 mins non-use
1*1.5V AAA long battery life, User replaceable battery and high-impedance plane
electrode.
Field throw measurement( Auto Lock Function)
Please wipe up the electorde with clean tissue or cloth before using.
Do not throw or beat ,squash or twist the tester deliberately.
Do not expose to the direct sunlight or
put in high humidity or high temperature environment .