Page 1: ...Document reference U1283_RQ_2210 Document version 9 Status Pending Approval date xxxx xx xx Approver XX I FORM W1600 Wireless Acoustic Monitoring Module ...

Page 2: ...ts Updated texts 3 2019 12 23 YG Updated images descriptions Updated text 4 2019 12 30 TB Updated images 5 2020 05 07 TB Updated I O text 6 2020 06 08 YG Updated to CLB128304 7 2020 10 01 TB Updated network requirements 2 2 1 8 2020 10 15 RL Added Port 1 configuration for P2501 9 2020 12 17 TB Updated product regulations and added 1 4 8 product standards References Ref Doc ID Version Document titl...

Page 3: ...______________17 2 2 1 Extra requirements________________________________________________________17 2 2 2 Compatibility_____________________________________________________________17 2 2 3 Network requirements _____________________________________________________18 2 2 4 Precautions______________________________________________________________18 2 3 INSTRUCTIONS____________________________________...

Page 4: ...f 29 2 10 1 Module identification ______________________________________________________27 2 10 2 Lost communication _______________________________________________________27 2 10 3 Error reporting ___________________________________________________________28 3 MANUFACTURER CONTACT INFORMATION _____________________________________ 29 ...

Page 5: ... facilitate this versatile use the W1600 module is supported by Building Blocks A Building Block determines the behaviour of the module s buttons and LEDs The second functionality includes two I O ports that don t deliver power The two ports can be found at the rear and can be configured as Input or Output The third functionality includes connecting an external Pear Push at the front left mini jac...

Page 6: ... of 29 Models Various button configurations are available as indicated in Image 2 below The configuration is indicated by a product number extension front panel left buttons right buttons i e W1600 PAE Image 1 Image 2 W1600 buttons Z ero blanco P atient nursecall U niversal A ssistance Z ero blanco U niversal E mergency Z ero blanco ...

Page 7: ...upply voltage 5 Vdc Supply current 2400 mA Power consumption average 1300 mW Communication interface 5 GHz WiFi Microphone Sensitivity 5 dBV Pa Speaker Sensitivity 3 dBV 1 W output 78 dBspl 1 W 1 m I O ports Digital Inputs ports 1 and 2 VINmax 24 Vdc InputLOW VINmax 0 8 Vdc InputHIGH VINmin 3 0 Vdc Outputs ports 1 and 2 OutputLOW Sink Imax 50 mA 5 0 Vmax OutputHIGH Source Imax 0 1 mA 3 0 Vmax Outp...

Page 8: ...HIGH Source Imax 0 1 mA 3 0 Vmax Power supply output Left front jack Output voltage 5 Vdc Max current 50 mA 1 4 3 Connection Specifications 1 4 3 1 Front connections Image 3 W1600 front connection Front connections J5 3 5mm 4p mini jack J5 Pear Push port Analogue 1 GND 2 Output Open Collector 3 Input A D 4 5Vdc 50mA J5 counterparts 3 5mm 4p mini jack plug Wiring J5 Recommended 4p stranded wire Max...

Page 9: ...ptor Model KSA 15E 051300HE WH J2 3p pin header I O port 1 PWR Only for powering P2501 Pullcord Imax 50 mA 5 0 Vmax 2 GND 3 I O port 1 J3 2p pin header I O port 1 GND 2 I O port 2 J2 counterparts Option 1 3p plug connector push in connector Manufacturer Phoenix Contact Type no FK MPT 0 5 3 ST 3 5 Part no 1913934 Option 2 3p plug connector screw connection Manufacturer Phoenix Contact Type No PT 1 ...

Page 10: ... 3 5 Part no 1984015 Important Use of ferrules is mandatory Wiring J2 J3 Massive 0 12 0 5 mm2 AWG 26 20 Solid wire Both Phoenix connectors with Push in or Screw connection are possible Stranded wire Only 8p plug connector with screw connection is possible Please note Use of ferrules is mandatory Maximum cable length J2 J3 The maximum cable length depends on the amount of current that is drawn by t...

Page 11: ...s Index Default colour Remark 1 RED RGB Button 1 indicator default Nurse call 2 GREEN RGB Button 2 indicator default Presence 3 RED RGB Button 3 indicator default Assistance 4 YELLOW RGB Button 4 indicator default none 5 BLUE RGB Button 5 indicator default none 6 RED Fixed Button 1 ring indicator default Nurse Call 7 BLUE Fixed Speech indicator Privacy LED 8 Speaker Speaker 1 4 4 2 Rear indicators...

Page 12: ...ult none 6 Light sensor Ambient light measurement for brightness adjustment 7 Microphone Microphone for speech or AM2 8 Identify Activated by holding a magnet at position 2 seconds Network presence Identify notification of W1600 to the system 1 beep can be heard when magnet is positioned correctly 5 seconds Safe shutdown manual Position magnet until 1 short beep is heard and hold at this position ...

Page 13: ...ns Declaration of Conformity DoC Directive 2014 53 EU of 16 April 2014 concerning radio equipment Hereby CLB bv declares that this wireless device is in compliance with the essential requirements and other relevant provisions of Directive 2014 53 EU Note Observe national and local regulations where the device is used This device may be restricted for use depending on the local network The operatio...

Page 14: ...nts 1 4 9 Radio Specifications EIRP average equivalent isotropically radiated power Type Frequency range Output power Bluetooth LE 2402 2480 MHz 40 channels 2 7 dBm IEEE 802 11b 2412 2472 MHz 13 channels 15 6 dBm IEEE 802 11a n ac 20 40 80 Mhz 5180 5240 MHz 4 2 1 channels 14 6 dBm IEEE 802 11a n ac 20 40 80 Mhz 5260 5320 MHz 4 2 1 channels 14 9 dBm IEEE 802 11a n ac 20 40 80 Mhz 5500 5700 MHz 8 4 ...

Page 15: ...erence U1283_RQ_2210 Status Pending Version 9 Approver XX Filename U1283_RQ_2210_IFORM_W1600 doc page 15 of 29 1 7 Hardware overview Image 7 W1600 surface mount assembled unit Dimensions mm Image 8 W1600 surface mount exploded view ...

Page 16: ..._RQ_2210 Status Pending Version 9 Approver XX Filename U1283_RQ_2210_IFORM_W1600 doc page 16 of 29 1 Cut parts 2 Break out parts 3 Place conduit reducer K25 NL 25 x 13 mm K25 UK 25 x 16 mm K10 UK 16 x 10 mm Image 9 Connecting conduit reducers ...

Page 17: ...nt only for connecting conduits types K25 NL 25 x 13 mm K25 UK 25 x 16 mm K10 UK 16 x 10 mm Printed documents Installation manual 2 2 Installation Requirements 2 2 1 Extra requirements Item Model variant note Installation equipment not provided by CLB Screw driver for fixing the mounting bracket Hex screw driver for locking the assembled unit Network WiFi 5GHz 2 2 2 Compatibility The table below c...

Page 18: ...strongly recommended to only use an official Raspberry Pi USB C 3A Power supply Raspberry Pi 4 Model B o USB power cables shall not be extended to prevent loss of sufficient power during start up 2 2 4 Precautions This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency RF Exposure Guidelines This equipment should be ins...

Page 19: ... Port must be configured as input Image 10 Typical Input Potential free contact Typical Input Contact Potential Port must be configured as input for external controlling of internal logic ports Image 11 Typical input contact potential External device can have an output voltage up to 24Vdc W16000 PORT GND PORT 1 2 GND PORT GND PORT 1 2 GND GND OUTPUT External device 12V W16000 ...

Page 20: ...Port must be configured as output Image 12 Typical output sink External device can have an output voltage up to 24Vdc Typical Output Source Port must be configured as output for controlling external logic ports Ports are not driven by current Image 13 Typical output source PORT GND PORT 1 2 GND 12V W16000 PORT GND PORT 1 2 GND GND External device W16000 INPUT ...

Page 21: ...must be configured as combined Input Output Image 14 Typical combined input output internal power supply 2 3 3 Maintenance Instructions Clean the surface of this module with a moist cloth The surface of this module can be disinfected with 70 isopropyl alcohol IPA 70 Do not use aggressive cleaning agents Only authorized personnel are allowed to open this module for maintenance GND PORT 1 5V GND W16...

Page 22: ...with screw connection Manufacturer Phoenix Contact Type No PT 1 5 3 PVH 3 5 Part no 1984028 2p connector J3 For use see 1 4 3 2 Option 1 Description 2p plug with push in spring connection Manufacturer Phoenix Contact Type no FK MPT 0 5 2 ST 3 5 Part no 1913921 Option 2 Description 2p plug with screw connection Manufacturer Phoenix Contact Type No PT 1 5 2 PVH 3 5 Part no 1984015 2 5 Settings 2 5 1...

Page 23: ...nfigured in order to connect to the required WiFi network These settings can be configured via the CLB DDC of CLB Configurator To access the W1600 it is preconfigured to connect to the wireless network with SSID CLB Config Once the network settings have been changed the W1600 will always try to connect to the configured network first on startup The W1600 connects by default to a predefined configu...

Page 24: ... to CLB Device Manager YES NO W1600 in same subnet as CLB server YES Connect laptop to same subnet as W1600 NO Use Configurator or DCC to configure the applicable CLB Server WiFi network and Device Manager W1600 will reboot after writing settings Make sure to enable the default CLB Config WiFi network Finalise W1600 configuration in Configurator W1600 configured in CLB system NO YES W1600 Normal o...

Page 25: ...ions The minimum time between reporting an audio notification to the system 1s to 30s 30s Button configuration Min LED brightness idle The minimum brightness of the button LED s in idle mode 0 to 50 1 Max LED brightness idle The maximum brightness of the button LED s in idle mode 0 to 50 35 Pear push handset Min LED brightness idle The minimum brightness of the pear push LED s in idle mode 0 to 50...

Page 26: ... Other installation precautions Take all necessary precautions to safely install the hardware 2 7 3 1 Connecting peripherals on mini jack connector via safe release cables The W1600 is able to detect mini jack connectors in order to prevent a possible short circuit or unintended message when connecting or disconnecting peripherals However this detection mechanism does not work when connecting the ...

Page 27: ...1600 module Answer 1 No for the W1600 this is where the microphone is located As mentioned in this I Form the W1600 module has only 2 I O ports on the rear of the module 2 10 Troubleshooting 2 10 1 Module identification From the Configurator software the module can be identified On the W1600 all LED indicators will blink and a tone is played from the speaker during the identification process 2 10 ...

Page 28: ...ort circuit Error Button 5 of the module is pressed for more than 60s Probably caused by a short circuit In this case the hardware has to be replaced Pear push button short circuit Error One or more buttons of a connected Pear push device is pressed for more than 60s Probably caused by a short circuit In this case the hardware has to be replaced Codec could not be initialized Error There is a prob...

Page 29: ...600 WAMM Reference U1283_RQ_2210 Status Pending Version 9 Approver XX Filename U1283_RQ_2210_IFORM_W1600 doc page 29 of 29 3 Manufacturer Contact Information CLB bv G G Schipperstraat 24 1483 GE De Rijp The Netherlands ...