5. Verify the HEPA filter is seated.
• Holding the power head on its side, examine the HEPA Filter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
–
If it is not, rotate it clockwise until fully seated.
6. Replace the power head.
• Position the power head on the tank.
• Rotate the power head so that the power switch on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.
Replace the pre-filter every five (5) bag filter changes or when it becomes visibly dirty.
1. Safe the vacuum.
• Disconnect the vacuum from the power source.
• Remove all hoses from the vacuum.
2. Remove the power head.
• Unlatch the power head from the tank.
• Lift the power head and the attached HEPA filter off the tank using the top handle.
• Carefully place the power head on the floor – avoid damaging the HEPA filter.
3. Remove the pre‑filter.
• The pre-filter is wrapped around the HEPA filter and secured with Velcro.
• Find the seam and carefully peel the Velcro apart.
• Dispose of the pre-filter according to company policy.
4. Install a new pre‑filter.
• Unfold a new pre-filter and remove the thin Velcro cover strip from the Velcro hooks.
• Wrap the pre-filter tightly around the HEPA filter.
• Secure the pre-filter by adhering the Velcro hooks to the side of the pre-filter.
5. Verify the HEPA filter is seated.
• Holding the power head on its side, examine the HEPA Filter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
–
If it is not, rotate it clockwise until fully seated.
6. Replace the power head.
• Position the power head on the vacuum tank.
• Rotate the power head so that the power switch on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
BAG FILTER CHANGE
PRE‑FILTER CHANGE