Clayton Power LPS II Series Manual And Safety Instructions Download Page 4

Warranty 

CAUTION & WARNING:

DO NOT USE OR ATTEMPT TO USE THIS PRODUCT UNTIL YOU HAVE READ THIS USER MANUAL 

IN ITS ENTIRETY. IMPROPER INSTALLATION OR USAGE OF THIS DEVICE MAY BE HAZARDOUS 

AND MAY CAUSE DAMAGE TO OTHER ELECTRICAL EQUIPMENT AND WILL VOID WARRANTY.

Clayton Power warrants, to the original purchaser only, for a period of 24 months from the date of 

purchase, that the Clayton Power device will be in good working order when properly installed and 

operated as described in this manual.

If the device fails within this period of time in normal use, Clayton Power will, without charge, 

at the  place  of  Clayton  Power’s  choosing,  repair  or  replace  the  device  -  with  new  or  

reconditioned  parts or a new or reconditioned device as Clayton Power deems necessary.

This warranty is not valid in cases of:

Usage against the recommendations of this manual.

Usage in applications outside of general automotive, solar, industrial or marine applications 

without the agreement of Clayton Power.

Device modification or repair without written authorization from Clayton Power.

Reverse  polarity,  excessive overload,  general  abuse,  neglect,  wear  &  tear,  ingress  of  liquids  

(water, oil, acid, or otherwise), foreign objects, lightning strikes, over or under voltage, RFI/EMI, 

etc.

Obtaining Warranty Service: 

To obtain warranty service, please contact the outlet at which you purchased your product. Do not 

contact Clayton Power directly. For warranty service provide the following:

• Proof of purchase

• The unit model number

• The unit serial number

• A brief description of the application and problem including any failure codes displayed on the 

unit.

• Contact your Clayton Power dealer for an authorization number prior to dispatch - do not send 

without authorization.

Once this number has been obtained, please carefully pack your unit and send (freight paid)to the 

Clayton Power dealer.

• Please note that the unit contains Lithium batteries and must be shipped as dangerous  goods 

according to UN3480 Lithium-Ion Batteries. 

Copyright

The information contained within this document remains the sole property of Clayton Power. 

No part of this document may be copied or reproduced in any form or by any means, and the 

information contained within is not to be communicated to third parties, without the prior written 

consent of Clayton Power.

Front

1  Display

2  12 V DC Power Button On/Off

3  230 V AC Power Button On/Off

4  Down Button

5  Up Button

6  Ok/Menu

7  Return

8  M12 - Data front

9  Serial number 

10 RCD - Residual-current device

11  230 output - Schuko socket

12  Air cooling - Front

Back 

13  Air cooling - Back

14  DC out

15  DC in

16  M12 - remote

17  M12 data

18  C1 (D+)

19  C2 (Solar +)

20 Label

21  AC out

22 AC in

Dept.

Technical reference

Created by

Approved by

Document type

Document status

Title

DWG No.

Rev.

Date of issue

Sheet

06/05/2021

1/1

000418 SubAssembly

Mads Lauenborg

11

9

10

1

2

12

3

4

5 6

7

8

Dept.

Technical reference

Created by

Approved by

Document type

Document status

Title

DWG No.

Rev.

Date of issue

Sheet

06/05/2021

1/1

000417 SubAssembly

Mads Lauenborg

13

14

15

16

17

18

19

20

21

22

6

7

Summary of Contents for LPS II Series

Page 1: ...Manual and safety instructions English LPS II Series ...

Page 2: ...not let children or animals come in contact with the unit or power connections Dangers involved in case of fire Danger of dust particle explosions Decomposition through fire or heat under development of toxic and cauterizing gases Combustion gasses which strongly irritate eyes and respiratory organs General actions to be taken by the driver if these dangers occur Turn off the engine Put a warning ...

Page 3: ...service providers You can find more information about the service options on our service page Disposal Batteries marked with the recycling symbol must be processed via a recycling agency recognized by official authority in the given country If agreed the unit may be returned to the manufacturer for proper disposal Batteries must not be mixed with any kind of domestic or industrial waste Installati...

Page 4: ...e provide the following Proof of purchase The unit model number The unit serial number A brief description of the application and problem including any failure codes displayed on the unit Contact your Clayton Power dealer for an authorization number prior to dispatch do not send without authorization Once this number has been obtained please carefully pack your unit and send freight paid to the Cl...

Page 5: ...0 A DC output voltage 10 14 4 VDC 10 14 4 VDC 10 14 4 VDC DC output charge current Continuously 90A 90A 90A DC output discharge current Continuously 180A 180A 180 A DC output discharge current 1min 270A 270A 350 A Solar input charging power max 400W 400W 400 W Solar input voltage 15 50 VDC 15 50 VDC 15 50 VDC Solar input charging current max 15 A 15 A 15 A Input signals 5 C1 C2 M12 x 3 C1 C2 M12 x...

Reviews: