9
VOLERO BATTEN AQUA
WARNING:
no alcohol
11
WARNING
- IP66 fixture
- Failure to completely remove power from fixture prior to servicing can lead to serious injury or death.
For additonal service information please contact [email protected]
IMPORTANT
The screws to be removed have rubber sleeve gaskets at the threaded end of the screw. DO NOT LOOSE these. They must be reinstalled when
reassembly is done. If these rubber sleeve gaskets are damaged, they must be replaced with exact original equipment (OE) parts, we also suggest to
replace the rubber sleeve gasket every 2 years.
To maintain IP66 rating each cover has rubber gasket on it. If any rubber gasket is lost or damaged, it must be replaced by an original equipment
(OE) part. We also suggest to replace the rubber sleeve gasket every 2 years.
CAUTION:
•
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The
frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of
the working environment (air humidity, presence of dust, salinity, etc.).
It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
- General cleaning of internal parts.
- Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Claypaky.
- General visual check of the internal components, cabling, mechanical parts, etc.
- Electrical, photometric and functional checks; eventual repairs.
Cleaning the lenses
Only use neutral soap and water to clean the lenses, then dry it carefully with a soft, non-abrasive cloth. (WARNING: the use of alcohol or any other
detergent could damage the lenses).
4.2 Periodical cleaning & Caution
Parts requiring frequent cleaning.
Light collimation system
This product contains internal light
collimation system. Avoid intense
light from any angle.