Fasten the black (negative) cable lug to the "-" distribution panel.
iv.
Connect the DC power cable to the DC terminal port on the PSU.
v.
Repeat the previous 2 steps for a second DC PSU, if it is installed.
The DC distribution panel should now be powered on and then the following checks performed:
1.
Verify that the first PSU's LED is illuminated.
2.
If a second DC PSU is installed, power on the second power distribution.
3.
Verify the second PSU's LED is illuminated.
4.
Verify cOS Core startup.
Restarting the 6000 Series
In order to restart the 6000 Series hardware manually, the On/Off rocker switch should be held in
and then released. This will restart the 6000 Series and reinitialize cOS Core so that it boots up
again. This process can also be initiated through cOS Core. For example, using the CLI
shutdown
command.
Important: Protecting against power surges
It is recommended to consider the purchase and use of a separate surge protection unit
from a third party for the power connection to the NetWall 6000 Series hardware. This is
to ensure that the appliance is protected from damage by sudden external electrical
power surges through the power cable.
Surge protection is particularly important in locations where there is a heightened risk of
lightning strikes and/or power grid spikes.
Any surge protection unit should be installed exactly according to the manufacturer's
instructions since correct installation of such units is vital for them to be effective.
Chapter 3: Installation
36