00MB1282 Iss 02
Consort Equipment Products Ltd
Registered Office: Thornton Industrial Estate
Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172
Fax: 01646 695195
BS EN ISO 9001 Registered Company No FM12671
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR
Sun-Zone
Radiant Heaters
Catalogue Numbers HE6502 (2 kW) & HE6503 (3 kW)
PLEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE
1. RANGE
There are 2 models in the Sun-Zone range:
C
AT
N
O
L
OADING
A
T
240
V
W
EIGHT
K
G
O
VERALL
L
ENGTH
(M
ETRES
)
HE6502 2
kW 1.40
1.31
HE6503 3
kW 2.09
1.72
Sun-Zone provides a wide beam distribution of radiant heat. Each unit is supplied complete with a fitted metal
sheathed wire element, wire-guard and a pair of mounting brackets. Sun-Zone heaters are not flameproof and
should not be used in hazardous areas.
2. INSTALLATION
(a)
It is important that Sun-Zone is not mounted close to a wall or ceiling.
Minimum offset distances are shown in Fig 1.
(b)
Sun-Zone heaters should be mounted at a minimum height of 2.1 metres above floor level.
(c)
Sun-Zone may be wall or ceiling mounted, chain or conduit suspended as shown in Fig 2.
Fixing Centres (metres)
C
AT
N
O
B
RACKET
/C
HAIN
S
USPENDED
C
ONDUIT
HE6502 1.17
1.25
HE6503 1.57
1.66
Sun-Zone may be mounted in a number of ways. Six methods are illustrated.
WARNING – THIS APPLIANCE MUST BE EARTHED