background image

00MB1282 Iss 02 

 

Consort Equipment Products Ltd 

Registered Office:  Thornton Industrial Estate 
Milford Haven, Pembrokeshire, SA73 2RT 
Tel:  01646 692172 

Fax:  01646 695195 

 

BS EN ISO 9001 Registered Company No FM12671

 

 

 

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR

 

Sun-Zone 

Radiant Heaters

 

Catalogue Numbers HE6502 (2 kW) & HE6503 (3 kW)

 

 

 

PLEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE 

1. RANGE 

 
There are 2 models in the Sun-Zone range: 

 

C

AT 

N

O

 

L

OADING 

A

240

V

 

W

EIGHT 

K

G

 

O

VERALL 

L

ENGTH 

(M

ETRES

HE6502 2 

kW  1.40 

1.31 

HE6503 3 

kW  2.09 

1.72 

 

Sun-Zone provides a wide beam distribution of radiant heat.  Each unit is supplied complete with a fitted metal 
sheathed wire element, wire-guard and a pair of mounting brackets.  Sun-Zone heaters are not flameproof and 
should not be used in hazardous areas. 
 

2. INSTALLATION 

 
(a) 

It is important that Sun-Zone is not mounted close to a wall or ceiling. 
Minimum offset distances are shown in Fig 1. 

 

 

 
(b) 

Sun-Zone heaters should be mounted at a minimum height of 2.1 metres above floor level. 

(c) 

Sun-Zone may be wall or ceiling mounted, chain or conduit suspended as shown in Fig 2. 

 

 

Fixing Centres (metres) 

 

C

AT 

N

O

 

B

RACKET

/C

HAIN 

S

USPENDED

 

C

ONDUIT

 

HE6502 1.17 

1.25 

HE6503 1.57 

1.66 

Sun-Zone may be mounted in a number of ways.  Six methods are illustrated. 

 

 

WARNING – THIS APPLIANCE MUST BE EARTHED 