Network Tester
Art.no 38-3970
Model TCT-108
Please read the entire instruction manual before use and save it for future reference. We reserve the right
for any errors in text or images and for making any necessary technical changes to this document. If you
should have any questions concerning technical problems please contact our Customer Services.
Product description
• Detachable “Remote” unit for measuring at both ends of the cable.
• Indicates whether the cable is complete, broken or short-circuited.
• Indicates whether the cable is straight or crossed.
• Requires no special battery, operates on a 9 V alkaline battery.
• Connections for both TP cable (RJ45) and ISDN cable (RJ11).
Operation
Inspecting TP cable (RJ45) and ISDN cable (RJ11)
Note:
Never connect the network tester to a network which is in use and is active, disconnect the cables
before testing them.
1. Connect one end of the cable to the Master unit and the other end to the Remote unit.
Detach the Remote unit and connect it to the other end of the cable if the cable is already installed.
2. Turn the on/off switch to
ON
(or
S
for slow testing)
3. Read the LEDs on the Master Unit.
4. The LEDs (1–8 and G) will flash in pairs on both units simultaneously.
• If the cable is OK the Master and Remote will flash in unison: 1 - 1, 2 - 2, 3 - 3, etc.
• If the cable is defective no LEDs will be lit.
• If “G” flashes during testing, the cable is shielded.
• If the connected cable is crossed, Master and Remote will start flashing out of sync:
1 - 3, 2 - 4, 3 - 1, etc.
Note:
• ISDN cable (RJ11) has 6 wire cores (1–6).
• TP cable (RJ45) has 8 cores (unshielded cable) or 8 cores + shield (G).
• The on/off switch has 3 positions: “OFF”, “ON” and “S” (slow testing).
Disposal
When it is time to dispose of this product, do so in accordance with local regulations.