AC/DC adaptor

Art.no  18-2933 / 36-5930
Model  SMP-27WME-UK / SMP-27WME

Please read the entire instruction manual 
before using the product and then save it 
for future reference. We reserve the right 
for any errors in text or images and any 
necessary changes made to technical data. 
In the event of technical problems or other 
queries, please contact our Customer 
Services.

Use

1.  Make sure that the connected device’s 

power consumption does not exceed 
the adaptor’s maximum output power.

2.  Find out which of the provided DC 

connectors fits your product (try them 
for size loose).

3.  There are two polarities for DC voltage, 

positive and negative. The AC/
DC adaptor is made for devices 
with a positive (+) or negative (−) 
central conductor. The polarity of 
the interchangeable DC connectors can 
be reversed to the correct polarity.

4.  Check the polarity markings on the pro-

duct you wish to connect, adjust the DC 
connectors like this:

 

-

Negative (−) on the centre pin: 

 

Turn the DC connector so that 
the (−) symbol is seen in front of 
the TIP mark.

 

-

Positive (+) on the centre pin: 

 

Turn the DC connector so that 
the (+) symbol is seen in front of 
the TIP mark.

5.  Make sure that the DC connector 

is pressed all the way into the cable 
connection.

6.  Set the desired output voltage (3 V/5 V/ 

6 V/7.5 V/9 V/12 V) using a small 
screwdriver and plug the cable with 
the correct DC connector on the end 
into the socket of the device to be 
powered by the adaptor.

7.  Connect the adaptor to a power point, 

the LED should light up.

8.  Switch on the connected device.

Warning:

•  The wrong voltage or polarity can 

damage the connected device.

•  Only connect devices that have a power 

consumption of max 27 W.

•  Turn off the connected device before 

connecting/disconnecting the adaptor.

•  Do not position the adapter where it is 

exposed to moisture or water.

Specifications

Rated voltage: 100–240 V AC, 50/60 Hz
Output voltage (stabilized): 3 V/5 V/6 V/ 
7.5 V/9 V/12 V, max 2.25 A

Disposal

This product should be disposed of in 
accordance with local regulations. If you are 
unsure how to proceed, contact your local 
council.

Summary of Contents for SMP-27WME-UK

Page 1: ... pro duct you wish to connect adjust the DC connectors like this Negative on the centre pin Turn the DC connector so that the symbol is seen in front of the TIP mark Positive on the centre pin Turn the DC connector so that the symbol is seen in front of the TIP mark 5 Make sure that the DC connector is pressed all the way into the cable connection 6 Set the desired output voltage 3 V 5 V 6 V 7 5 V...

Page 2: ...odukten som ska anslutas vänd batteriproppen så här Negativ på centrumstift Vänd batteriproppen så att symbolen syns framför TIP Positiv på centrumstift Vänd batteriproppen så att symbolen syns framför TIP 5 Se till att batteriproppen är helt intryckt i kabelanslutningen 6 Ställ in önskad utspänning 3 V 5 V 6 V 7 5 V 9 V 12 V med hjälp av t ex en liten skruvmejsel och anslut kabeln med rätt batter...

Page 3: ...kten slik Negativ på sentrumstift Vend batteripluggen slik at symbolet syns foran TIP Positiv på sentrumstift Vend batteripluggen slik at symbolet syns foran TIP 5 Pass på at batteripluggene er helt inntrykt 6 Still inn ønsket ut spenning 9 V 12 V 3 V 5 V 6 V 7 5 V f eks med hjelp av en liten skrutrekker og koble så kabelen med riktig batteriplugg til det produktet som skal drives av eliminatoren ...

Page 4: ...paisuus 4 Tarkista liitettävän laitteen napaisuus ja käännä liitin seuraavalla tavalla Negatiivinen keskijohdin Käännä liitin niin että kuvake on TIP tekstin etupuolella Positiivinen keskijohdin Käännä liitin niin että kuvake on TIP tekstin etupuolella 5 Varmista että liitin on painettu kaapeliliitännän pohjaan 6 Valitse lähtöjännite 3 V 5 V 6 V 7 5 V 9 V 12 V esim pienellä ruuvitaltalla ja liitä ...

Page 5: ...eiter Den Hohlstecker so umpolen dass das Symbol vor TIP zu sehen ist Positiv am Innenleiter Den Hohlstecker so umpolen dass das Symbol vor TIP zu sehen ist 5 Sicherstellen dass das der Hohlstecker vollständig auf den Kabelanschluss geschoben ist 6 Die gewünschte Spannung 3 V 5 V 6 V 7 5 V 9 V 12 V z B mithilfe eines kleinen Schraubendrehers einstellen und das Kabel mit dem richtigem Hohlstecker f...

Reviews: