Test and care

1.

Test the smoke alarms at least once every month, and preferably after
being away for a prolonged period by pushing the test button. Press
and hold the test button to test the smoke alarm. The alarm should
then emit three short beeps followed by a flashing LED.

2.

Below the test button is a red LED which flashes every 10 second. It
shows that the smoke alarm is working.

3.

Vacuum the smoke alarms and wipe them with a damp clot every six
months or when undesirable alarm occur

4.

Replace the smoke alarm after 10 years

5.

To remove the smoke alarm for maintenance or changing, press in its
lock tabs according to the illustration and twist it anticlockwise. The
smoke alarm will then automatically deactivate.

alarm, or the breach of this or any other 
guarantee, expressed or implied or for 
damage caused by failure to abide by 
the instructions supplied. This guarantee 
does not affect your statutory rights.

Instruction Manual

Optical Smoke Alarm

Art.no:   36-6143 

Model:  Deltronic PT-8221

Please read the entire instruction manual before use and save it for future 
reference. We reserve the right for any errors in text or images and for 
making any necessary technical changes to this document. If you should 
have any questions concerning technical problems please contact our 
Customer Services.

Location of smoke alarms

Fit smoke alarms on each floor level in your home. Good places to

fit alarms are where you can hear them throughout your home. For
example: -Top of the staircase - Stair landings - Between living and
sleeping areas etc.
For additional protection, fit a smoke alarm in each room – except in

the kitchen/cooking area, bathrooms or garage – where smoke or
steam can set them of accidentally.
Always make sure that the sound of the smoke alarms can be heard

in the bedrooms.
Additional smoke alarms could give earlier warning, and increase the

chance of safe escape and rescue from a fire.

BEDROOM

BEDROOM

BEDROOM

LOUNGE

KITCHEN

BASEMENT

GARAGE

DINING

ROOM

KITCHEN

LOUNGE

BEDROOM

BED-

ROOM

BEDROOM

MULTIPLE STOREY HOMES

WITH TWO SLEEPING AREAS

SINGLE STOREY HOME

 WITH TWO SLEEPING AREAS

SMOKE ALARMS, MINIMUM PROTECTION
SMOKE ALARMS, RECOMMENDED PROTECTION

SMOKE ALARMS, MINIMUM PROTECTION

 

SMOKE ALARMS, RECOMMENDED PROTECTION

 

Silencer / Pause function

 

(sensitivity reduction)

Placing the smoke alarm close to a kitchen, fireplace or other heat sources 
can sometimes cause accidental triggering. In these cases the smoke 
alarm can be temporarily turned off by pressing the test button. Thereafter, 
the alarm will then automatically revert back to normal sensitivity. The red 
LED will flash every 12 seconds to indicate that it is in pause mode and will 
automatically revert back to normal operation after 10 minutes.
The low-battery warning is often activated at night and can be temporar-
ily paused for ten hours by pressing the test button. This allows you to 
replace smoke alarm the next day or a more appropriate time.

Do not fit smoke alarms in the following locations:

Near the angle between the ceiling and walls where the air stands still and

• 

form a “dead air space” that prevents smoke from reaching the smoke alarm.

In kitchens, garages, or bathrooms or other high humidity areas,

where combustion particles or moisture can cause nuisance alarms. 

Near fresh air vents, fans or extractors. Draughts can blow smoke

away from the alarm.
In areas where excessive dust or dirt could contaminate the sensing

chamber, making it over sensitive or impairing smoke entry.
In areas where the ambient temperature is not controlled, and may drift

• 

below 5

˚

C or above 40

˚

C. High humidity could cause nuisance alarms.

Within 1.5 m (60”) of a fluorescent or halogen light fitting, or LED-lamps,

• 

which emits electrical ‘noise’ that can prevent correct smoke alarm operation.
In insect infested areas. Insects can clog

smoke openings and or cause nuisance
alarms.
Do not paint the smoke alarm.

Installation

1. Remove the smoke alarm from its mounting

plate. The smoke alarm comes with its mounting plate

loosely attached so that it is deactivated.

2. If the smoke alarm should accidently sit tight and be

activated while still in its packaging, push in its lock tabs

and twist the alarm anticlockwise to loosen and deactivate it.

3. Select an appropriate location for alarm installation

(see section above).

4. Screw the mounting plate onto the ceiling using the

included screws and wall plugs.

5. Align the arrow on the back of the smoke alarm to the

arrow on the mounting plate and set the alarm into place.

6. Once the alarm is in place, twist it clockwise to secure it into its 

correct position. A click will be heard when it is securely locked into 

place.

7. The integrated batteries will then automatically power on and the 

smoke alarm will be activated.

Alarm signal & LED indication

Full alarm, smoke 

detected

Repeated 3-beep pattern every 

4 seconds with accompanying 

flashing LED

■■■ ■■■ ■■■

Low battery

One beep every minute

■         ■         ■

The test button is stuck

One beep every 11 seconds

■     ■     ■     ■

Technical problem

Double beep every minute

■■     ■■     ■■

Low battery warning & unit replacement

This smoke alarm has a built-in non-replaceable Lithium battery with a life 
expectancy of over 10 years. Approximately 1 month before the battery is 
completely discharged, the smoke alarm will start to emit short signals at 
about one-half minute intervals. It is then time to replace the smoke alarm. The 
alarm works as normal during this time. Waste electrical products should not 
be disposed of with household waste. Please recycle where facilities exist. 

Warranty

Clas Ohlson UK Ltd guarantees to you, as a purchaser, that the enclosed 
smoke alarm will be free from defects in material, workmanship, or design 
under normal use and service for a period of 10 years. This guarantee is not 
assignable. Our liability to you, under this guarantee is limited to repairing or 
replacing any part which we find to be defective in material, workmanship or 
design, free of charge to the customer, upon sending (postage paid) or supp-
lying the alarm with proof of purchase to any of our branches. The terms 
of this guarantee will not apply if the alarm has been modified, dismantled, 
contaminated, damaged neglected or otherwise abused, or if this manual 
have not been followed. The liability of 

C

las 

O

hlson UK Ltd arising from the 

sale of this alarm or under the terms of this guarantee shall not in any case 
exceed the cost of replacement of the 
alarm. In no case, shall Clas Ohlson UK 
Ltd be liable for consequential loss or 

0

086

damage resulting from the failure of the 

Deltronic, 

E A Rosengrensgata

 4,

S-4

21

 

31

 

Västra Frölunda

0086-CPR-624017 / KM 623822

EN 14604:2005

Model PT-8221

Smoke alarm devices

For declaration of performance 

visit: www.deltronic.se

Test your smoke alarms

at least every month

Clean you smoke alarms

at least twice a year

The sealed-in battery does

not need to be replaced

After 10 years of use,

replace the alarm instead

ALARMS MOUNTED ON

CEILINGS SHOULD BE AT

LEAST 50 CM FROM WALLS

WHEN MOUNTED ON WALL

(NOT RECOMMENDED)

15 CM FROM CEILING

ALARMS MOUNTED ON

SLOPED CEILINGS SHOULD BE

AT LEAST 1 M HORIZONTALLY

FROM THE APEX

”DEAD AIR SPACE” - WITHOUT

CIRCULATING AIR SUPPLY

SECURITY 

TAG

LED LIGHT

TEST 

BUTTON

Ver. 2018-08-01