1.
Test the smoke alarms at least once every month, and preferably after
being away for a prolonged period by pushing the test button. Press
and hold the test button to test the smoke alarm. The alarm should
then emit three short beeps followed by a flashing LED.
2.
Below the test button is a red LED which flashes every 10 second. It
shows that the smoke alarm is working.
3.
Vacuum the smoke alarms and wipe them with a damp clot every six
months or when undesirable alarm occur
4.
Replace the smoke alarm after 10 years
5.
To remove the smoke alarm for maintenance or changing, press in its
lock tabs according to the illustration and twist it anticlockwise. The
smoke alarm will then automatically deactivate.
alarm, or the breach of this or any other
guarantee, expressed or implied or for
damage caused by failure to abide by
the instructions supplied. This guarantee
does not affect your statutory rights.
Instruction Manual
Optical Smoke Alarm
Art.no: 36-6143
Model: Deltronic PT-8221
Please read the entire instruction manual before use and save it for future
reference. We reserve the right for any errors in text or images and for
making any necessary technical changes to this document. If you should
have any questions concerning technical problems please contact our
Customer Services.
Location of smoke alarms
Fit smoke alarms on each floor level in your home. Good places to
•
fit alarms are where you can hear them throughout your home. For
example: -Top of the staircase - Stair landings - Between living and
sleeping areas etc.
For additional protection, fit a smoke alarm in each room – except in
•
the kitchen/cooking area, bathrooms or garage – where smoke or
steam can set them of accidentally.
Always make sure that the sound of the smoke alarms can be heard
•
in the bedrooms.
Additional smoke alarms could give earlier warning, and increase the
•
chance of safe escape and rescue from a fire.
BEDROOM
BEDROOM
BEDROOM
LOUNGE
KITCHEN
BASEMENT
GARAGE
DINING
ROOM
KITCHEN
LOUNGE
BEDROOM
BED-
ROOM
BEDROOM
MULTIPLE STOREY HOMES
WITH TWO SLEEPING AREAS
SINGLE STOREY HOME
WITH TWO SLEEPING AREAS
SMOKE ALARMS, MINIMUM PROTECTION
SMOKE ALARMS, RECOMMENDED PROTECTION
SMOKE ALARMS, MINIMUM PROTECTION
SMOKE ALARMS, RECOMMENDED PROTECTION
Silencer / Pause function
(sensitivity reduction)
Placing the smoke alarm close to a kitchen, fireplace or other heat sources
can sometimes cause accidental triggering. In these cases the smoke
alarm can be temporarily turned off by pressing the test button. Thereafter,
the alarm will then automatically revert back to normal sensitivity. The red
LED will flash every 12 seconds to indicate that it is in pause mode and will
automatically revert back to normal operation after 10 minutes.
The low-battery warning is often activated at night and can be temporar-
ily paused for ten hours by pressing the test button. This allows you to
replace smoke alarm the next day or a more appropriate time.
Do not fit smoke alarms in the following locations:
Near the angle between the ceiling and walls where the air stands still and
•
form a “dead air space” that prevents smoke from reaching the smoke alarm.
In kitchens, garages, or bathrooms or other high humidity areas,
•
where combustion particles or moisture can cause nuisance alarms.
Near fresh air vents, fans or extractors. Draughts can blow smoke
•
away from the alarm.
In areas where excessive dust or dirt could contaminate the sensing
•
chamber, making it over sensitive or impairing smoke entry.
In areas where the ambient temperature is not controlled, and may drift
•
below 5
˚
C or above 40
˚
C. High humidity could cause nuisance alarms.
Within 1.5 m (60”) of a fluorescent or halogen light fitting, or LED-lamps,
•
which emits electrical ‘noise’ that can prevent correct smoke alarm operation.
In insect infested areas. Insects can clog
•
smoke openings and or cause nuisance
alarms.
Do not paint the smoke alarm.
•
Installation
1. Remove the smoke alarm from its mounting
plate. The smoke alarm comes with its mounting plate
loosely attached so that it is deactivated.
2. If the smoke alarm should accidently sit tight and be
activated while still in its packaging, push in its lock tabs
and twist the alarm anticlockwise to loosen and deactivate it.
3. Select an appropriate location for alarm installation
(see section above).
4. Screw the mounting plate onto the ceiling using the
included screws and wall plugs.
5. Align the arrow on the back of the smoke alarm to the
arrow on the mounting plate and set the alarm into place.
6. Once the alarm is in place, twist it clockwise to secure it into its
correct position. A click will be heard when it is securely locked into
place.
7. The integrated batteries will then automatically power on and the
smoke alarm will be activated.
Alarm signal & LED indication
Full alarm, smoke
detected
Repeated 3-beep pattern every
4 seconds with accompanying
flashing LED
■■■ ■■■ ■■■
Low battery
One beep every minute
■ ■ ■
The test button is stuck
One beep every 11 seconds
■ ■ ■ ■
Technical problem
Double beep every minute
■■ ■■ ■■
Low battery warning & unit replacement
This smoke alarm has a built-in non-replaceable Lithium battery with a life
expectancy of over 10 years. Approximately 1 month before the battery is
completely discharged, the smoke alarm will start to emit short signals at
about one-half minute intervals. It is then time to replace the smoke alarm. The
alarm works as normal during this time. Waste electrical products should not
be disposed of with household waste. Please recycle where facilities exist.
Warranty
Clas Ohlson UK Ltd guarantees to you, as a purchaser, that the enclosed
smoke alarm will be free from defects in material, workmanship, or design
under normal use and service for a period of 10 years. This guarantee is not
assignable. Our liability to you, under this guarantee is limited to repairing or
replacing any part which we find to be defective in material, workmanship or
design, free of charge to the customer, upon sending (postage paid) or supp-
lying the alarm with proof of purchase to any of our branches. The terms
of this guarantee will not apply if the alarm has been modified, dismantled,
contaminated, damaged neglected or otherwise abused, or if this manual
have not been followed. The liability of
C
las
O
hlson UK Ltd arising from the
sale of this alarm or under the terms of this guarantee shall not in any case
exceed the cost of replacement of the
alarm. In no case, shall Clas Ohlson UK
Ltd be liable for consequential loss or
0
086
damage resulting from the failure of the
Deltronic,
E A Rosengrensgata
4,
S-4
21
31
Västra Frölunda
0086-CPR-624017 / KM 623822
EN 14604:2005
Model PT-8221
Smoke alarm devices
For declaration of performance
visit: www.deltronic.se
Test your smoke alarms
at least every month
Clean you smoke alarms
at least twice a year
The sealed-in battery does
not need to be replaced
After 10 years of use,
replace the alarm instead
ALARMS MOUNTED ON
CEILINGS SHOULD BE AT
LEAST 50 CM FROM WALLS
WHEN MOUNTED ON WALL
(NOT RECOMMENDED)
15 CM FROM CEILING
ALARMS MOUNTED ON
SLOPED CEILINGS SHOULD BE
AT LEAST 1 M HORIZONTALLY
FROM THE APEX
”DEAD AIR SPACE” - WITHOUT
CIRCULATING AIR SUPPLY
SECURITY
TAG
LED LIGHT
TEST
BUTTON
Ver. 2018-08-01