MAINTENANCE
Very little regular maintenance is required, other than general cleaning on the outside of
the machine. Wipe over with a clean dampened soft cloth, use a mild household detergent
if necessary. Never use harmful chemicals.
If detergents have been used in the washer, it is important to flush the system with clean
water for a few minutes after use.
If there is a danger of freezing, anti freeze should be mixed with the flush water, or the
system must be completely drained.
Storage
Store in an upright position, completely drained of water, in a dry frost free location.
Engine
Refer to the engine handbook, and service accordingly.
NOTE: Engine oil should be checked before each use.
Pump
Change the oil after the first 50 hours of service, and every 500 hours thereafter.
DO NOT attempt to carry out any mechanical repairs yourself. Please contact your CLARKE
dealer for Service and repairs. If the pump is ever dismantled for servicing and/or repair,
remember to top up with 15w/40 non synthetic oil (100ml).
Periodically unscrew and remove the hose connector from the pump to expose the suction
filter, carefully remove filter inspect for damage and signs of wear etc, clean filter by holding
under the tap and allow the running water to flush out any impediment, DO NOT use tools
to clean the filter or damage will occur. When clean refit to the pump body followed by the
hose connector.
TROUBLE SHOOTING
FAULT
PROBABLE CAUSE
REMEDY
The pump doesn’t
reach the necessary
pressure.
Water inlet clogged.
Clean the water inlet filter.
Suction/ delivery valves are
clogged or worn out.
Lance nozzle incorrect or
worn out.
Clean or replace valves.
Check and/or replace.
Fluctuating pressure.
Pump sucking air from
connections or hoses.
Check all connections and
tighten if necessary.
Regulating valve sticking.
Slacken off regulating screw,
then retighten.
Water leaking from
the pump.
Worn seals.
Check and replace if
necessary.
Machine becomes
noisy.
Worn bearings.
Check and replace if
necessary.
No water from
nozzle when trigger
is operated..
Nozzle blocked.
Clean nozzle with the nozzle
cleaning pin supplied.
-9-