Scrub System
65
Service Manual – MA50 15B
16.
Cut the wire ties, and disconnect the brush motor connector
17. Install the new brush motor in the reverse order
Shop Measurements
•
Amp draw of brush motor (free spin) - 2.8 amps
•
Amp draw of brush motor (with brush turning on floor) - 9.5 amps
•
Voltage measured at Control PCB terminals - 24 volts DC when POWER and BRUSH switches are ON
Summary of Contents for MA50 15B
Page 2: ...Clarke MA50 15B 03 2016 Form No 56043172 Service Manual Model Numbers Clarke MA50 15B English...
Page 15: ...Control System 14 Service Manual MA50 15B Solution Control Valve Solution Solenoid...
Page 21: ...Electrical System 20 Service Manual MA50 15B Wiring Harness Diagram BR 12 17A 17A...
Page 48: ...Recovery System 47 Service Manual MA50 15B Vacuum Hose Pick Up Tube Adapter Vacuum seals x 2...
Page 69: ...Solution System 68 Service Manual MA50 15B Solution Valve Solenoid Solution Switch...
Page 78: ...Squeegee System 77 Service Manual MA50 15B Squeegee Assembly Squeegee Thumb Screws...
Page 79: ...Squeegee System 78 Service Manual MA50 15B Squeegee Lift Handle Squeegee Lift Cable...