Page 1: ...1103...
Page 2: ...tion manual thoroughly and carefully follow all directions given This is for your own safety and for that of others around you and will also help you achieve long and trouble free service from your pu...
Page 3: ...s likely to shift 9 If pumping water which is liable to freeze the pump MUST be run continuously otherwise the pump must be removed from the water and stored in a frost free location 10 If the pump is...
Page 4: ...this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol or...
Page 5: ...d run it for a few minutes on completion to ensure it is completely cleansed of all contaminants The maximum depth to which the pump should be submerged is 10 Metres The pump is fitted with a Float Sw...
Page 6: ...ilar and ensure that this type of support is not likely to shift The pump should be well clear of silt mud or any type of marine growth IMPORTANT ALWAYS raise and lower the pump using a rope attached...
Page 7: ...0o C for example it will shut off automatically Switch the pump OFF and disconnect from the mains supply Check for blockages and allow the motor to cool at least 15 minutes before attempting to restar...
Page 8: ...start consult your CLARKE dealer for advice B PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked clean as necessary 2 Discharge tube clogged or obstructed clear as necessary 3 The...