MAINTENANCE

This pump should require no maintenance other than regular cleaning. 

If the pump starts to show signs of wear or damage, contact your CLARKE 
dealer for advice. 

CLEANING

1. Check the pump installation regularly to ensure the water inlet is clear of 

leaves or other debris.

2. Take extra care to remove any debris from around the impeller.

NOTE:

Do not attempt to repair the pump yourself, as you may damage the 
waterproof seal and invalidate your guarantee. Repairs must be 
carried out by your CLARKE dealer, or contact the CLARKE Service 
Department, on 020 8988 7400.

STORAGE

When the pump is not being used for extended periods, clean and dry it 
thoroughly and store in indoors. if the pump is left in water, it must be run at 
least once a week to prevent it from seizing up.

SPECIFICATIONS

WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT 
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED, 
ENSURE THE CIRCUIT BREAKER IS OPEN.

Voltage

230V~50Hz

Outlet Thread Diameter

1½“BSP

Power 750W

Maximum Head Height

8 m

Maximum Depth

7 m

Maximum Flow

217 l/min.

Maximum Water Temperature

35

o

C

Maximum Particle Size

35 mm

Weight

5.1 kg

Cable Length

10 m

Dimensions (D x W x H) 

157 x 203 x 351 mm

Summary of Contents for 7236046

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0917 iss 3 ORIGINAL INSTRUCTIONS 750W SUBMERSIBLE PUMP WITH BUILT IN FLOAT SWITCH MODEL NO PSV5A PART NO 7236046...

Page 2: ...r not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect...

Page 3: ...r outdoor use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not...

Page 4: ...t be connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the...

Page 5: ...ptor is supplied The hose adaptor can be screwed onto the elbow if required 1 Trim the adaptor to the required size Reducing the hose diameter will effect the maximum flow rate 2 Connect a suitable ho...

Page 6: ...E PUMP 1 Connect the mains plug to the mains supply Always use a high sensitivity residual current device RCD which has a tripping current of less then 30 mA 2 Switch the mains power supply on The pum...

Page 7: ...guarantee Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 STORAGE When the pump is not being used for extended periods clean and dry it tho...

Page 8: ...your CLARKE dealer for advice 7 Water level has dropped below the minimum of 90mm PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the outlet is not clogged or obstruct...

Page 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS LIST DIAGRAM...

Page 10: ...th 31 Front Bushing 7 Deflector Rod Guide 32 O Ring 8 Self Tapping Screw 33 Front Cover 9 Rear Deflector Rod 34 Mechanical Seal 10 Float 35 O Ring 11 Shield 36 Adjustable Washer 12 Dial Block 37 Impel...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 12: ......

Reviews: