background image

Summary of Contents for 1600DV

Page 1: ...USER INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0618 ISS 1 GAS HEATERS MODEL NOS 900DV 1600DV 2100DV PART NOS 6920175 6920191 6920196 ...

Page 2: ...lty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights FUNCTION AND OPERATING PARAMETERS This is a gas powered heater It s intended use is for drying and the warming of commercial industrial buildings where adequate ventilation is provided It must be operated as prescribed in the operati...

Page 3: ...condition anaemia 3 People under the influence of alcohol 4 Those living working at high altitude WHAT TO DO IF YOU SUSPECT CO POISONING Get fresh air immediately Open doors and windows switch off the heater and leave the area See your doctor immediately or go to hospital let them know that you suspect CO poisoning They can do a blood or breath test to check Do not use the heater until it has been...

Page 4: ...r as stated on page 8 Keep the heater as far as practical from propane tanks and do not point the heater directly at any propane tank Stand the heater on a stable level surface whilst hot or operating If the heater overturns a fire can occur Keep children and animals away from heater at all times Use heater in accordance with all fire regulations Do not use heater for domestic heating in living or...

Page 5: ...Cleaning and user maintenance shall not be made by children without supervision If the supply cable is damaged it must be replaced by a special cable or assembly available from the manufacturer or its service agent SAFETY SYMBOLS The following safety symbols may be found on the product ENVIRONMENTAL RECYCLING POLICY Through purchase of this product the customer is taking on the obligation to deal ...

Page 6: ...lows Connect GREEN YELLOW cord to terminal marked with a letter E or Earth symbol Connect BROWN cord to terminal marked with a letter L Connect BLUE cord to terminal marked with a letter N If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewirable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric sh...

Page 7: ...otify your Clarke dealer immediately Your heater is fully assembled only the electrical and gas supplies need connecting Retain any plastic cover caps attached to the inlet connector and hose regulator assembly for future storage PROPANE GAS SUPPLY These heaters are designed for use with PROPANE GAS ONLY Gas cylinders are not supplied but are readily available from builders merchants or gas suppli...

Page 8: ...Correct all leaks immediately IMPORTANT The gas hose and cylinder must ALWAYS be located well behind the heater In order to reduce the risk of icing up when operating at long periods at maximum capacity you should use a larger capacity gas bottle or two three bottles in parallel as shown in Fig 2 The Tee piece and pigtails are readily available from your builders merchants or gas supplier CHANGING...

Page 9: ...tu hr is a minimum requirement These heaters are specified as requiring a minimum ventilation of 3 sq ft per 100 000BTU hr OPERATING SPACE Do not obstruct the air intake to the heater and allow the following clearances from combustible surfaces Outlet 8 feet 2 4 m Sides 2 feet 0 6 m Top 6 feet 1 8 m Rear 2 feet 0 6 m Keep the heater as far as practical from propane tanks and never point the heater...

Page 10: ... system 3 The ignition system 4 The safety control system AIR SYSTEM An axial fan which is energised when switching on provides the air flow through the combustion chamber to provide a stream of hot air from the heater GAS SYSTEM The gas supply to the machine is by means of a high pressure hose connected to an LPG Liquid Propane Gas cylinder via a pressure regulator When the mains supply is switch...

Page 11: ...ditionally the machine is equipped with thermal overload protection which will intervene should the unit overheat shutting off the electrical supply STARTING PROCEDURE 1 Ensure there is sufficient gas and that it is correctly connected 2 Open the supply valve on the gas cylinder and fully open the regulator valve adjacent to the gas inlet pipe 3 Plug the heater in to a suitable power supply 4 Set ...

Page 12: ...ure the fan is operating and that the air inlet and outlet are completely clear Also ensure that the electrode gap is correct and that the electrode is clean see Maintenance Should the thermal overload protection feature operate and the spark plug is seen to be operating shut off the gas supply and allow the unit to cool for at least 10 minutes with the fan running before attempting to relight the...

Page 13: ...components is gained by removing the access panel under the base of the heater which is secured by screws around the edge MONTHLY WHEN IN CONSTANT USE Check the spark plug for cleanliness and correct operation Have the gap re set to no more than 5mm by your Clarke service engineer Check the condition of the gas hose If there are any signs of deterioration it should be renewed using only a Clarke o...

Page 14: ...l not ignite Connection installation incorrect Check that installation instructions are followed No spark at spark plug due to loose HT lead or PCB fault Check spark plug wire Tighten or re attach if loose If condition persists contact your Clarke dealer for advice Heater stops during operation Excessive or insufficient gas supply Check pressure regulator replace if necessary Check that fan motor ...

Page 15: ...ng operation keeping the gas valve button depressed for longer Weak gas supply Increase flame intensity control valve setting Model Number 900DV 1600DV 2100DV Dimensions L x W x H mm 500x215x370 500x215x370 640x235x385 Weight 6 65 kg 6 7 kg 8 6 kg Fuse Rating 230V only 13A 13A 13A Operating Voltage 230V 50Hz 1ph 110V 50Hz 230V 50Hz 1ph 110V 50Hz 230V 50Hz 1ph 110V 50Hz Rated Input Power 100W 110W ...

Page 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM DEVIL 900DV 1600DV ...

Page 17: ...tor 6 Orifice Assembly 25 Solenoid Valve Assembly 7 Flame Holder Assembly 26 Solenoid Valve Assembly Nut 8 High Limit Switch Bracket 27 Flame Intensity Control Knob 9 High Limit Switch 28 Control Box 10 Spark Plug Nut 29 Dual Voltage Switch 11 Spark Plug Washer 30 Dual Voltage Switch Cover 12 Spark Plug 31 Power Switch 13 Fan 32 Bushing Strain Relief 14 Motor Assembly 33 Power Cord Assembly 15 Inl...

Page 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM DEVIL 2100DV ...

Page 19: ...Fitting Connector 7 Flame Holder Assembly 27 Solenoid Valve Assembly 8 High Limit Switch Bracket 28 Solenoid Valve Assembly Nut 9 High Limit Switch 29 Flame Intensity Control Knob 10 Spark Plug Nut 30 Control Box 11 Spark Plug Washer 31 Dual Voltage Switch 12 Spark Plug 32 Dual Voltage Switch Cover 13 Fan 33 Power Switch 14 Motor Assembly 34 Bushing Strain Relief 15 Motor Mounting Bracket 35 Power...

Page 20: ...20 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING DIAGRAMS ...

Page 21: ...21 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 22: ...22 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com ...

Page 23: ...23 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com ...

Page 24: ......

Reviews: