ClareOne CLR-C1-DWCNT Instruction Manual Download Page 1

ClareOne Door Window Sensor with External Contact                      Installation Manual                                                                                                                                     

CLR-C1-DWCNT

 

                                                                                                                                                        CLR-C1-DWCNT  IM V3  05012020 

 

Description 

 

The Door/Window Sensor with Extended 

Contact is a supervised, wireless sensor 

that detects the opening and closing of 

doors or windows. The sensor and 

magnet are mounted using screws 

(included) or double-sided adhesive tape 

(included).  

 

When activated, the sensor transmits an 

open (trip) or close (restore) signal to the 

panel. These are the signals the unit provides: 

supervisory, tamper and low battery (as needed). The 

sensor is powered by (2) replaceable 3-VDC, lithium 

coin-cell batteries. 

 

 

 

 

 

 

 

   

 

 

 

 

 

External Contact 

 

 

Note: Only one set of contacts can be used at one time 

the internal or external, for added security the internal 

reed switch can be cut. 

 

 

Installation Guidelines 

 

1. Remove the transmitter’s cover by pressing in on the 

small rectangular latch on the end of the cover and lift 

up. 

2. Mount the sensor base directly to the surface using 

the mounting tape provided. Make sure to align the 

mounting tape with the tamper pull put area on the 

bottom of the sensor to insure proper tamper operation.  

3. Mount the magnet next to the sensor and align the    

magnet with the mark on the side of the sensor, using  

the mounting tape provided, or connect an external  

contact to the terminals. 

4. Remove the battery isolator tabs from both batteries  

on the sensor. 

5. Replace the cover on the transmitter. 

6. Enroll the senor into the control panel according the 

instructions. 

 

 

Programming  

The following steps describe the general guidelines for 

programming the sensor into panel memory. Refer to the 

specific panel’s documentation for complete 

programming details.  

 1. Set the panel to the program mode. 

 2. Proceed to the SENSORS menu. 

 3. Select the appropriate sensor group and sensor  

 number assignments. 

 4. When prompted by the panel to trip the sensor for 

learning by remove the sensor cover and if present pull 

the battery pull tabs or enter the sensor ID#. The system 

should acknowledge the sensor by touchpad display 

and/or audio (depending on the panel).  

 5. Exit program mode.  

 

Testing the Sensor  

1. Set the panel to the sensor test mode.  

2. Take the sensor and magnet to the desired mounting 

location, making sure to line up their alignment marks 

with each other. Trip the sensor by pulling the magnet 

away from the sensor.  

3. Monitor the system after tripping the sensor. Refer to 

the specific panel documentation for interpretation of the 

results to ensure desired signal strength is achieved.  

     Note: 

If a low battery alarm occurs,   

     replace the battery within 7 days.  

 

CAUTION

: Battery may explode if mistreated. Do not 

recharge, disassemble or dispose of in fire.  

 

Mounting the Sensor 

 

Mount the sensor using the supplied mounting screws 

for permanent mounting installations or using the 

supplied double-sided tape is optional.  

    Note: 

The gap between the sensor and    

    magnet should not exceed a maximum of 5/8”.  

 

For Additional Tamper Security  

Punch out the tamper cover on the bottom of the sensor, 

and using the small screw secure it to the mounting 

location, when the sensor is removed “tampered” the tab 

remains providing a tamper condition. 

 

 

 

 

 

 

 

 

Tamper 

switch 

Cover 

Latch 

Batteries 

Terminals 

Cover 

Latch 

Tamper 

Base 

 

Note: Do not exceed 50ft when wiring 

to an external contact 