15
EN
CLAGE
Your product was manufactured from high-quality, reusable materials and components. Please
respect in case of discarding that electrical devices should be disposed of separately from
household waste at the end of their service life. Therefore, please take this device to a municipal
collection point that return used electronic devices to the recycling system. Disposing it cor-
rectly will support environmental protection and will prevent any potential negative effects on
human beings and the environment that could arise from inappropriate handling of these devices
3. Environment and recycling
at the end of their service life. Please contact your local authority for further details of your near-
est designated collection point or recycling site.
Business customers: If you wish to discard equipment, please contact your dealer or supplier for
further information.
4. Dimensions
The following regulations must be observed:
• VDE 0100
• EN 806
• Installation must comply with all statutory regulations, as well as those of the local electricity
and water supply companies.
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
5. Installation
Based on the national constitution guidelines a general test
certificate concerning the evidence of applicability of noise
behaviour is granted.
Dimensions in mm (fig. D1)
16952
Installation site
• Appliance must only be installed in frost-free rooms. Never expose appliance to frost.
• The Appliance must be wall mounted and has to be installed with water connectors down-
ward or alternative transversely with water connections left.
• The appliance complies with protection type IP25 and may therefore be installed in protec-
tion zone 1 according to VDE 0100 part 701.
• In order to avoid thermal losses, the distance between the instantaneous water heater and
the tap connection should be as small as possible.
• The appliance must be accessible for maintenance work.
• Plastic pipes may only be used if they conform to DIN 16893, Series 2.
• The specific resistance of the water must be at least 1100 Ω cm at 15 °C. The specific resist-
ance can be asked for with your water distribution company.
• Do not install the device in the immediate proximity of metal surfaces to allow a reliable
wireless connection and an optimal wireless range.
Thoroughly rinse the water supply pipes before installation to remove soiling from the pipes.
1. Using a 12 mm hexagon socket screw key, screw the screw-in nipples according to image
manual into the wall connections as shown in. The seals must be fully screwed into the
thread.
2. Hold the included mounting template according to image manual on the wall, mark the drill
holes according to the template and drill them using a 6 mm drill.
3. Pull down the faceplate and unscrew the main hood screw to open the appliance.
4. Loosen the knurled nut of the wall bracket, remove the wall bracket and screw it on the wall.
Offset tiling or uneven surfaces can be compensated by up to 30 mm with the aid of the
spacers supplied. The spacers are fitted between the wall and the wall bracket.
Installing the wall bracket
Note: Fasten the screw nuts with caution, to avoid damage to the valves or the piping system.
• As shown in the illustration, screw the cold water connection piece with the union nut and
the ½ inch seal onto the cold water connection.
• Screw the hot water connection piece with the union nut and the ½ inch seal onto the hot
water connection.
(fig. D2).
Installing connection pieces
• The electrical power supply cable may be connected in the upper part. In such case, the
connection will be done according to the description “Electrical connection from above” in
online manual.
• Install the appliance according to image manual.
Installing the appliance
Mounting the remote control’s wall bracket
• Before attaching the wall bracket to the wall, ensure that the remote control has radio con-
tact to the instantaneous water heater from its designated position.
• The wall bracket of the remote control can either be attached securely with the included
adhesive tape, after stripping off the protection film (as shown in the figure B1), on a rigid
board (e.g. tile) or with suitable dowels (Ø 4 mm) and screws (as shown in the figure B2).
• When mounting with adhesive tape, ensure that the mounting surface is dry and free of
grease and soap.
• When using the adhesive tape it is not possible to further adjust the position because of
the strong adherence of the glue. Therefore, pay attention to a horizontal alignment when
attaching it.
• The remote control is magnetically retained at the wall bracket.
• Keep the remote control and wall bracket away from credit cards or other cards with mag-
netic strips. The built in magnets can damage the card’s magnetic strip.
Note: Do not expose the remote control to moisture.
Note: Accessories and surface mounting
For further informations please use the online operation and installation
instruction. Please follow the link below or use the QR code via smart-
phone or tablet.
https://www.clage.de/links/gma/DSX-Touch-GMA-9120-34385